![Furuno RC-1800T Installation Manual Download Page 23](http://html1.mh-extra.com/html/furuno/rc-1800t/rc-1800t_installation-manual_2350553023.webp)
2. WIRING
2-7
2.6
Charger Unit (BC-6158-SS/6200)
According to the battery used, set the output voltage of the charger unit to 26.7 VDC
(default setting, for a valve-regulated lead-acid battery) or 28 VDC. For a flooded lead-
acid battery, change the output voltage from 26.7 VDC to 28 VDC.
1. Loosen four screws to remove the front panel of the charger unit, referring to at
2. Draw out the charger unit, then set the toggle switch to 28 VDC. The toggle switch
(S1) is on the 05P0659 board located on the side of the charger unit.
3. Reinsert the charger unit.
4. Check the “SS (TICK)” checkbox.
5. At the rear of the control panel, remove four screws on the 05P0607 board to re-
move the board.
Battery
Output voltage
Valve-regulated lead-acid battery, maintenance free
26.7 VDC (default)
Flooded lead-acid battery
28 VDC
Charger Unit
05P0659 Board
05P0659 Board
(Side of the
charger unit)
28 VDC
Toggle switch
(S1)
Toggle switch
(S1)
Put check mark.
Blank
Rear of the front panel
05P0607 Board
05P0607 Board
Control Panel (Front view)
Control Panel (Rear view)