13. INSTALLATION
13-6
13.3.3
How to mount a transducer inside the hull
The transducer may also be installed inside the hull on FRP boats. However, this in-
stallation method affects the ability to detect the bottom, fish and other objects be-
cause the ultrasound pulse is weakened when it passes through the hull.
Note:
This mounting method should not be used to mount the transducer that sup-
ports the ACCU-FISH
TM
and/or bottom discrimination display feature, since perfor-
mance is greatly degraded.
Necessary tools
The following tools are required:
Remarks on installation
Installation procedure
The attenuation of the ultrasound pulse varies with the thickness of the hull. Select a
location where attenuation is the lowest.
1. Select 2-3 locations considering the four points mentioned below.
2. Decide the most suitable site from the locations selected.
1) Connect the power cable and transducer cable to the display unit.
• Sandpaper (#100)
• Marine sealant
• Water-filled plastic bag
• Do the installation with the ship moored at a dock, etc. The water depth should be 6.5-
32 feet (2-10 meters).
• Turn off the engine.
• Do not power the unit with the transducer in the air, to prevent damage to the trans-
ducer.
• Do not use this method on a double layer hull.
• Before attaching the transducer to the hull, check that the site is suitable. Put the
transducer in a water-filled plastic bag. Connect the transducer to the display unit and
put the transducer on the installation site. Turn on the display unit and check that the
depth indication appears.
• Mount the transducer at a location 1/2 to 1/3 of the length of your boat from the
stern.
• The mounting location is between 15 to 50 cm from the centerline of the hull.
• Do not place the transducer over hull struts or ribs which run under the hull.
• Avoid a location where the rising angle of the hull exceeds 15°, to minimize the
effect of the boat's rolling.
1/3
1/2
Centerline
Transducer
mounting
location
50 cm
50 cm
15 cm
15 cm
Summary of Contents for GP-1870F
Page 1: ......
Page 44: ...1 OPERATIONAL OVERVIEW 1 28 This page is intentionally left blank...
Page 118: ...9 MEMORY CARD OPERATIONS 9 6 This page is intentionally left blank...
Page 142: ...11 CUSTOMIZING YOUR UNIT 11 6 This page is intentionally left blank...
Page 172: ...13 INSTALLATION 13 24 This page is intentionally left blank...
Page 186: ...APPENDIX 3 JIS CABLE GUIDE AP 14 This page is intentionally left blank...
Page 188: ...APPENDIX 4 INSTALLATION OF TEMPERATURE SENSORS AP 16...
Page 189: ...APPENDIX 4 INSTALLATION OF TEMPERATURE SENSORS AP 17...
Page 190: ...APPENDIX 4 INSTALLATION OF TEMPERATURE SENSORS AP 18...
Page 191: ...APPENDIX 4 INSTALLATION OF TEMPERATURE SENSORS AP 19...
Page 196: ...6 Apr 2012 H Maki D 1...
Page 197: ...6 Apr 2012 H Maki D 2...
Page 198: ...6 Apr 2012 H Maki D 3...
Page 199: ...6 Apr 2012 H Maki D 4...
Page 200: ...D 5...
Page 208: ......
Page 209: ......