2. HORIZONTAL MODE
2-23
3. Press the
TARGET LOCK
key.
Tilt, range and vertical bearing are automatically adjusted to track the location. Us-
ing the figure above as an example, the target lock mark is placed on location E.
Then, the equipment remembers the location of E and automatically changes the
tilt angle as the ship moves from position A through D. As long as the school of
fish E is stationary its echo is kept displayed on the screen.
4. To disable the target lock, press the
TARGET LOCK
key.
2.11.4
Target lock menu description
Target lock functions not previously mentioned are described below.
Tilt Interlock
: Provides automatic change of tilt angle and range or tilt angle in target
lock. (Setting options: [OFF], [Tilt], [Tilt & Range])
Mark Interlock
: Turns numeric/graphic data displays ON/OFF in target lock. [Off]
turns off both the estimate mark 1, 2 histogram and data display. [Estimate Mark] en-
ables the estimate mark 1, 2 histogram. [Est & Fish Info] enables the both the estimate
mark 1, 2 histogram and data display.
Tracking Data
: Selects which target lock tracking data to use, horizontal or slant, or
both horizontal and vertical.
Threshold
: Selects the minimum signal level to use in target lock tracking. The setting
range is 1 to 30. Target lock tracks a target whose signal level is greater than set here.
Bottom Threshold
: When a target is judged as a bottom echo, raise this setting to
differentiate bottom from target. The setting range is 0 to 5.
Target Speed Limit
: Sets maximum fish speed to track. The setting range is 1kn to
15kn.
Smoothing
: Sets smoothing rate for fish speed data. The higher the figure, the
smoother the position of the target lock target. Avoid oversmoothing, to prevent delay
in tracking when own ship or target moves suddenly. The setting range is 0.0 to 1.0.
Target SPD Update
: Sets the interval at which fish speed data is updated. The inter-
vals are 15, 30, 45 and 60 seconds.
Target Lock Window
: Selects the size of target lock detection area; normal, large,
largest. (The area is not indicated on the screen.)
Dimension Setup
: Sets dimension constant for calculation of weight (ton) of school
of fish from the dimension of the school of fish.
Volume Setup
: Sets volume constant for calculation of weight (ton) of school of fish
volume.
Summary of Contents for FSV85MK2
Page 12: ...SYSTEM CONFIGURATION xii This page is intentionally left blank ...
Page 74: ...2 HORIZONTAL MODE 2 44 This page is intentionally left blank ...
Page 128: ...4 SLANT MODE 4 36 This page is intentionally left blank ...
Page 132: ...5 NUMERIC GRAPHIC DATA DISPLAY 5 4 This page is intentionally left blank ...
Page 188: ...9 MAINTENANCE 9 24 This page is intentionally left blank ...
Page 199: ......