background image

www.furuno.com

All brand and product names are registered trademarks, trademarks 

or service marks of their respective holders.

12023SK Printed in Japan

Catalogue No. S-025a

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

FURUNO ELECTRIC CO., LTD.

Nishinomiya, Hyogo, Japan
www.furuno.com

FURUNO U.S.A., INC.

Camas, Washington, U.S.A.
www.furunousa.com

FURUNO (UK) LIMITED

Havant, Hampshire, U.K.
www.furuno.co.uk

FURUNO FRANCE S.A.S.

Bordeaux-Mérignac, France
www.furuno.fr

FURUNO ESPAÑA S.A.

Madrid, Spain
www.furuno.es

FURUNO DANMARK A/S

Hvidovre, Denmark
www.furuno.dk

FURUNO NORGE A/S

Ålesund, Norway
www.furuno.no

FURUNO SVERIGE AB

Västra Frölunda, Sweden
www.furuno.se

FURUNO FINLAND OY

Espoo, Finland
www.furuno.fi

FURUNO POLSKA Sp. Z o.o.

Gdynia, Poland
www.furuno.pl

FURUNO EURUS LLC

St. Petersburg, Russian Federation
www.furuno.com.ru

FURUNO DEUTSCHLAND GmbH

Rellingen, Germany
www.furuno.de

FURUNO HELLAS S.A.

Piraeus, Greece
www.furuno.gr

RICO (PTE) LTD

Singapore
www.rico.com.sg

1

  Volume/Power knob :

Sound volume control/Switching of Power ON/OFF

2

  RF GAIN knob :

Adjustment of reception gain

  PUSH TO ATT :

Press to activate/deactivate RF attenuator

3

              :

Long-press to transmit a DSC distress alert

4

              :

Composition of DSC message for distress alert

:

Composition of DSC message except for distress alert and DROBOSE (DSC relay on behalf of someone else*)

     Press             +           

  

:

Composition of DSC message for DROBOSE

5

              :

Activation of the brilliance control dialog box

:

Activation of tab segment control on the screen

:

Opening/closing of the menu dialog box

:

Deactivates alarm/deletion of error and pop-up messages/halting of DSC message composition/exiting from the 

message composition dialog box/distress cancellation/returning to a previous menu level

:

Switching the speaker ON/OFF

6

  PUSH TO ENTER knob :

Shifts the selector and pointer/adjusts the degree of parameter, i.e., brilliance and switch over the display mode

Press to confirm the entered values

7

              :

Switches to the DSC SCAN mode/if pressed during the DSC SCAN mode, routine scan will be halted

:

Sets to 2182 kHz SSB

:

Switches to radiotelephone mode, and if pressed in radiotelephone mode, channel setting box will be summoned

:

Used to enter the following number and symbols (. @ - _ / : 1) as well as quick access to short cut function

:

Used to enter A, B, C and 2, and to switch noise blanker setting ON/OFF

:

Used to enter D, E, F and 3, and to switch squelch setting ON/OFF

:

Used to enter G, H, I and 4 as well as quick access to short cut function

:

Used to enter J, K, L and 5, and to switch noise reduction setting ON/OFF

:

Used to enter M, N, O and 6

:

Used to enter P, Q, R, S and 7 as well as quick access to short cut function

:

Used to enter T, U, V and 8, and to switch notch filter ON/OFF

:

Used to enter W, X, Y, Z and 9 

:

Used to reduce the receiver volume of the handset/to shift the pointer in channel/frequency selection dialog box

:

Used to enter the number “0” , space and the following symbols (! “ # $ % & ‘ ( ) * + , - . / : ; < = > ? @ [ \ ] ^ - `{ } ~)/

to tune impedance between an antenna and a transceiver

:

Used to raise the receiver volume of the handset/to shift the pointer in channel/frequency selection dialog box

Numbers are assigned for each of the menu items, and the operator 
can access each of the menu items either by turning and pressing 
PUSH  TO  ENTER  knob  to  select  menu  items  or  simply  pressing 
number on the numeric keypad.

Simplified menu operation

Press

Press

Press

1

2

3

4

5

6

7

Control Panel

* composition and relay of the occurrence of a distress event obtained by non-DSC means

Models: FS-1575 (150 W)

FS-2575 (250 W)
FS-5075 (500 W)

S P E C I F I C A T I O N S

Option or connectable equipment

24 VDC

AC/DC Power Supply

PR-850A (FS-2575/5075)  PR-300 (FS-1575)

100/110/120/200/220/240 VAC

Antenna Coupler

AT-5075 (FS-2575/5075)

AT-1575 (FS-1575)

TX (duplex)* or

TX/RX (Semi-duplex/simplex)

RX

 (duplex)* 

NBDP Terminal Unit

IB-585

External Speaker

SEM-21Q

External Speaker

SEM-21Q

Printer

PP-510

DSC

Distress/

Safety 

DSC

Routine

WR 

Matching Box

ARD-1

BK Interface BK-300

Navigation equipment

Alarm System

Printer Interface

IF-8500

Alarm Unit IC-350

Preamp

FAX-5

Handset

HS-2003

Control Unit

FS-2575C

Control Unit

 (remote) 

FS-2575C

Handset

HS-2003

Transceiver Unit

FS-5075T for FS-5075

FS-2575T for FS-2575

FS-1575T for FS-1575

* Full duplex optionally available on the FS-5075 only

MODEL

OFFICIAL NAME OF EQUIPMENT

GENERAL CHARACTERISTICS

 

 

Rules and Regulations

Frequency Range
Number of Channels

Communication Mode

Class of Emission

TRANSCEIVER

RF Output Power

Antenna

Tuning Speed

Receiver Sensitivity

DSC

Receiving

Frequency
Message Storage

EQUIPMENT LIST

Standard

Option

1  Transceiver Unit 

2  Control Unit

3  Handset

4  Antenna Coupler

FS-1575T (FS-1575), 

FS-2575T (FS-2575),

FS-5075T (FS-5075)

FS-2575C

HS-2003

AT-5075 (FS-2575/5075)

AT-1575 (FS-1575)

1  Printer

2  Printer Interface

3  External Speaker

4  Control Unit

5  NBDP Terminal Unit

6  BK Interface

7  Whip Antenna

8  AC/DC Power Supply

9  Full Duplex Kit (for FS-5075)

10  Matching Box

11  Preamp

12  WR2 kit

PP-510

IF-8500

SEM-21Q 

FS-2575C

IB-585

BK-300

PR-850A (FS-2575/5075)

PR-300 (FS-1575)

OP05-125

ARD-1

FAX-5

OP05-123

1 Unit

1 Unit

1 Unit
1 Unit

FS-2575

SSB RADIOTELEPHONE

ITU-R M.1082-1, ITU-R M.1173, ITU-R M.476-5, ITU-R M.490, ITU-R M.491-1, ITU-R M.492-6,

ITU-R M.493-13, ITU-R M.541-9, ITU-R M.625-3, ITU-R M.821-1, IMO Res. A.694(17), IMO Res. A.806(19), 

IMO Res. MSC36 (63), IMO Res. MSC 68 (68), MSC/Circ. 862, IEC 61162-1 Ed. 4, IEC60945 Ed. 4,

ETS 300 067 ed. 1, EN 300 338-1 V1.3.1, EN 300 338-2 V1.3.1, EN 301 033 V1.3.1, EN 300 373-1 V1.3.1

1605.0kHz to 27500.0kHz

100kHz to 29999.99kHz

256 user-specified channels plus ITU, SSB/TELEX channels

J3E, H3E, A1A, J2B

250 W pep

10-18 m whip or wire

within 15 sec

less than +7 dBµV (4.0-29.99999 MHz, J3E) / less than +13 dBµV (1.6-4 MHz, J3E)

All DSC frequencies in MF/HF

DSC distress/safety frequencies: 2187.5 kHz, 4207.5 kHz, 6312.0 kHz, 8414.5 kHz, 12577.0 kHz, 16804.5 kHz

50 distress messages, plus 50 non-distress messages

50 messages, telephone no., frequencies, etc.

POWER SUPPLY

24 VDC, 100/110/120/200/220/240 VAC with optional AC/DC Power Supply PR-850A (FS-2575/5075) / PR-300 (FS-1575)

40 A (TX), 5.0 A (RX)

FS-1575

Simplex/Semi-duplex

150 W pep

TX:

RX:

General

Distress and safety

TX:

RX:

FS-5075

Simplex/Semi-duplex/Duplex (option)

500 W pep (HF) / 400 W pep (MF)

20 A (TX), 5.0 A (RX)

60 A (TX), 5.0 A (RX)

INTERCONNECTION DIAGRAM

CONTROL UNIT

ANTENNA COUPLER

Ø16

150 5.9”

57 2.24”

36 1.42”

650 25.59”

300 11.81”

300 11.81”

707  27.83”

365  14.37”
390  15.35”

20 0.79”

Ø16

40

1.57”

57 2.24”

150 5.9”

390  15.3”

416  16.4”

472  18.6”

12 0.47”

12 0.47”

100  3.94”

125  4.92”

125  4.92”

340  13.39”

100  3.94”

4-Ø7.5

400  15.75”

45

1.77” Ø8

140 5.51”

71.4 2.81”

478  18.82”

380  14.96”

4-7x10

FIXING HOLE

330  12.99”

74

2.91”

258  10.16”

297  11.69”

161  6.34”

93  3.66”

50

1.97”

24

0.94”

MAX 20

0.79”

5

0.2”

17

0.67”

108  4.25”

90  3.54”

208

8.19”

Ø16

40

1.57”

57 2.24”

150 5.9”

510  20.07”

536  21.1”

592  23.3”

12 0.47”

12 0.47”

100  3.94”

125  4.92”

125  4.92”

340  13.39”

100  3.94”

4-Ø7.5

208

8.19”

208

8.19”

FS-2575C

1.9 kg  4.2 lb

TRANSCEIVER UNIT

FS-5075T  

27 kg

59.5 lb

HANDSET

HS-2003

0.5 kg

1.2 lb

FS-2575T  

20 kg

44.1 lb

FS-1575T  

16 kg 

35.3 lb

AT-5075  

8.5 kg

18.7 lb

AT-1575  

2.6 kg

5.7 lb

47

1.85”

70

2.76

70

2.76”

100

3.94”

Ø8

400   15.75”

270   10.63”

4-Ø8

FIXING HOLE

491   19.33”

442   17.40” 412   16.22”

77

3.03”

55

2.17”

35

1.38”

200  7.87”

Summary of Contents for FS-1575 (150 W)

Page 1: ... Interface 3 External Speaker 4 Control Unit 5 NBDP Terminal Unit 6 BK Interface 7 Whip Antenna 8 AC DC Power Supply 9 Full Duplex Kit for FS 5075 10 Matching Box 11 Preamp 12 WR2 kit PP 510 IF 8500 SEM 21Q FS 2575C IB 585 BK 300 PR 850A FS 2575 5075 PR 300 FS 1575 OP05 125 ARD 1 FAX 5 OP05 123 1 Unit 1 Unit 1 Unit 1 Unit FS 2575 SSB RADIOTELEPHONE ITU R M 1082 1 ITU R M 1173 ITU R M 476 5 ITU R M...

Page 2: ...se in the Maritime Mobile Service ITU R M 493 13 High contrast 4 3 bright color LCD 480x272 pixels Capable of distress safety and routine communication Instant selection of 256 user specified channels with a rotary knob or direct keypad input Quick access to DSC message composition by dedicated keys on the control unit Full duplex kit available optional supply for the FS 5075 only Quick access to ...

Page 3: ...ressed in radiotelephone mode channel setting box will be summoned Used to enter the following number and symbols _ 1 as well as quick access to short cut function Used to enter A B C and 2 and to switch noise blanker setting ON OFF Used to enter D E F and 3 and to switch squelch setting ON OFF Used to enter G H I and 4 as well as quick access to short cut function Used to enter J K L and 5 and to...

Page 4: ... of equipment i e speaker ON OFF unread DSC message in the inbox hardware error etc Also MMSI is shown in radiotelephone and DSC scan displays 3 Tab segment Up to 7 active procedures can be displayed in this segment The procedures are for operating radiotelephone distress alert transmission distress alert reception general DSC message transmission and general DSC message reception 1 Status segment...

Reviews: