www.furuno.com
All brand and product names are registered trademarks, trademarks
or service marks of their respective holders.
12023SK Printed in Japan
Catalogue No. S-025a
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
FURUNO ELECTRIC CO., LTD.
Nishinomiya, Hyogo, Japan
www.furuno.com
FURUNO U.S.A., INC.
Camas, Washington, U.S.A.
www.furunousa.com
FURUNO (UK) LIMITED
Havant, Hampshire, U.K.
www.furuno.co.uk
FURUNO FRANCE S.A.S.
Bordeaux-Mérignac, France
www.furuno.fr
FURUNO ESPAÑA S.A.
Madrid, Spain
www.furuno.es
FURUNO DANMARK A/S
Hvidovre, Denmark
www.furuno.dk
FURUNO NORGE A/S
Ålesund, Norway
www.furuno.no
FURUNO SVERIGE AB
Västra Frölunda, Sweden
www.furuno.se
FURUNO FINLAND OY
Espoo, Finland
www.furuno.fi
FURUNO POLSKA Sp. Z o.o.
Gdynia, Poland
www.furuno.pl
FURUNO EURUS LLC
St. Petersburg, Russian Federation
www.furuno.com.ru
FURUNO DEUTSCHLAND GmbH
Rellingen, Germany
www.furuno.de
FURUNO HELLAS S.A.
Piraeus, Greece
www.furuno.gr
RICO (PTE) LTD
Singapore
www.rico.com.sg
1
Volume/Power knob :
Sound volume control/Switching of Power ON/OFF
2
RF GAIN knob :
Adjustment of reception gain
PUSH TO ATT :
Press to activate/deactivate RF attenuator
3
:
Long-press to transmit a DSC distress alert
4
:
Composition of DSC message for distress alert
:
Composition of DSC message except for distress alert and DROBOSE (DSC relay on behalf of someone else*)
Press +
:
Composition of DSC message for DROBOSE
5
:
Activation of the brilliance control dialog box
:
Activation of tab segment control on the screen
:
Opening/closing of the menu dialog box
:
Deactivates alarm/deletion of error and pop-up messages/halting of DSC message composition/exiting from the
message composition dialog box/distress cancellation/returning to a previous menu level
:
Switching the speaker ON/OFF
6
PUSH TO ENTER knob :
Shifts the selector and pointer/adjusts the degree of parameter, i.e., brilliance and switch over the display mode
Press to confirm the entered values
7
:
Switches to the DSC SCAN mode/if pressed during the DSC SCAN mode, routine scan will be halted
:
Sets to 2182 kHz SSB
:
Switches to radiotelephone mode, and if pressed in radiotelephone mode, channel setting box will be summoned
:
Used to enter the following number and symbols (. @ - _ / : 1) as well as quick access to short cut function
:
Used to enter A, B, C and 2, and to switch noise blanker setting ON/OFF
:
Used to enter D, E, F and 3, and to switch squelch setting ON/OFF
:
Used to enter G, H, I and 4 as well as quick access to short cut function
:
Used to enter J, K, L and 5, and to switch noise reduction setting ON/OFF
:
Used to enter M, N, O and 6
:
Used to enter P, Q, R, S and 7 as well as quick access to short cut function
:
Used to enter T, U, V and 8, and to switch notch filter ON/OFF
:
Used to enter W, X, Y, Z and 9
:
Used to reduce the receiver volume of the handset/to shift the pointer in channel/frequency selection dialog box
:
Used to enter the number “0” , space and the following symbols (! “ # $ % & ‘ ( ) * + , - . / : ; < = > ? @ [ \ ] ^ - `{ } ~)/
to tune impedance between an antenna and a transceiver
:
Used to raise the receiver volume of the handset/to shift the pointer in channel/frequency selection dialog box
Numbers are assigned for each of the menu items, and the operator
can access each of the menu items either by turning and pressing
PUSH TO ENTER knob to select menu items or simply pressing
number on the numeric keypad.
Simplified menu operation
Press
Press
Press
1
2
3
4
5
6
7
Control Panel
* composition and relay of the occurrence of a distress event obtained by non-DSC means
Models: FS-1575 (150 W)
FS-2575 (250 W)
FS-5075 (500 W)
S P E C I F I C A T I O N S
Option or connectable equipment
24 VDC
AC/DC Power Supply
PR-850A (FS-2575/5075) PR-300 (FS-1575)
100/110/120/200/220/240 VAC
Antenna Coupler
AT-5075 (FS-2575/5075)
AT-1575 (FS-1575)
TX (duplex)* or
TX/RX (Semi-duplex/simplex)
RX
(duplex)*
NBDP Terminal Unit
IB-585
External Speaker
SEM-21Q
External Speaker
SEM-21Q
Printer
PP-510
DSC
Distress/
Safety
DSC
Routine
WR
Matching Box
ARD-1
BK Interface BK-300
Navigation equipment
Alarm System
Printer Interface
IF-8500
Alarm Unit IC-350
Preamp
FAX-5
Handset
HS-2003
Control Unit
FS-2575C
Control Unit
(remote)
FS-2575C
Handset
HS-2003
Transceiver Unit
FS-5075T for FS-5075
FS-2575T for FS-2575
FS-1575T for FS-1575
* Full duplex optionally available on the FS-5075 only
MODEL
OFFICIAL NAME OF EQUIPMENT
GENERAL CHARACTERISTICS
Rules and Regulations
Frequency Range
Number of Channels
Communication Mode
Class of Emission
TRANSCEIVER
RF Output Power
Antenna
Tuning Speed
Receiver Sensitivity
DSC
Receiving
Frequency
Message Storage
EQUIPMENT LIST
Standard
Option
1 Transceiver Unit
2 Control Unit
3 Handset
4 Antenna Coupler
FS-1575T (FS-1575),
FS-2575T (FS-2575),
FS-5075T (FS-5075)
FS-2575C
HS-2003
AT-5075 (FS-2575/5075)
AT-1575 (FS-1575)
1 Printer
2 Printer Interface
3 External Speaker
4 Control Unit
5 NBDP Terminal Unit
6 BK Interface
7 Whip Antenna
8 AC/DC Power Supply
9 Full Duplex Kit (for FS-5075)
10 Matching Box
11 Preamp
12 WR2 kit
PP-510
IF-8500
SEM-21Q
FS-2575C
IB-585
BK-300
PR-850A (FS-2575/5075)
PR-300 (FS-1575)
OP05-125
ARD-1
FAX-5
OP05-123
1 Unit
1 Unit
1 Unit
1 Unit
FS-2575
SSB RADIOTELEPHONE
ITU-R M.1082-1, ITU-R M.1173, ITU-R M.476-5, ITU-R M.490, ITU-R M.491-1, ITU-R M.492-6,
ITU-R M.493-13, ITU-R M.541-9, ITU-R M.625-3, ITU-R M.821-1, IMO Res. A.694(17), IMO Res. A.806(19),
IMO Res. MSC36 (63), IMO Res. MSC 68 (68), MSC/Circ. 862, IEC 61162-1 Ed. 4, IEC60945 Ed. 4,
ETS 300 067 ed. 1, EN 300 338-1 V1.3.1, EN 300 338-2 V1.3.1, EN 301 033 V1.3.1, EN 300 373-1 V1.3.1
1605.0kHz to 27500.0kHz
100kHz to 29999.99kHz
256 user-specified channels plus ITU, SSB/TELEX channels
J3E, H3E, A1A, J2B
250 W pep
10-18 m whip or wire
within 15 sec
less than +7 dBµV (4.0-29.99999 MHz, J3E) / less than +13 dBµV (1.6-4 MHz, J3E)
All DSC frequencies in MF/HF
DSC distress/safety frequencies: 2187.5 kHz, 4207.5 kHz, 6312.0 kHz, 8414.5 kHz, 12577.0 kHz, 16804.5 kHz
50 distress messages, plus 50 non-distress messages
50 messages, telephone no., frequencies, etc.
POWER SUPPLY
24 VDC, 100/110/120/200/220/240 VAC with optional AC/DC Power Supply PR-850A (FS-2575/5075) / PR-300 (FS-1575)
40 A (TX), 5.0 A (RX)
FS-1575
Simplex/Semi-duplex
150 W pep
TX:
RX:
General
Distress and safety
TX:
RX:
FS-5075
Simplex/Semi-duplex/Duplex (option)
500 W pep (HF) / 400 W pep (MF)
20 A (TX), 5.0 A (RX)
60 A (TX), 5.0 A (RX)
INTERCONNECTION DIAGRAM
CONTROL UNIT
ANTENNA COUPLER
Ø16
150 5.9”
57 2.24”
36 1.42”
650 25.59”
300 11.81”
300 11.81”
707 27.83”
365 14.37”
390 15.35”
20 0.79”
Ø16
40
1.57”
57 2.24”
150 5.9”
390 15.3”
416 16.4”
472 18.6”
12 0.47”
12 0.47”
100 3.94”
125 4.92”
125 4.92”
340 13.39”
100 3.94”
4-Ø7.5
400 15.75”
45
1.77” Ø8
140 5.51”
71.4 2.81”
478 18.82”
380 14.96”
4-7x10
FIXING HOLE
330 12.99”
74
2.91”
258 10.16”
297 11.69”
161 6.34”
93 3.66”
50
1.97”
24
0.94”
MAX 20
0.79”
5
0.2”
17
0.67”
108 4.25”
90 3.54”
208
8.19”
Ø16
40
1.57”
57 2.24”
150 5.9”
510 20.07”
536 21.1”
592 23.3”
12 0.47”
12 0.47”
100 3.94”
125 4.92”
125 4.92”
340 13.39”
100 3.94”
4-Ø7.5
208
8.19”
208
8.19”
FS-2575C
1.9 kg 4.2 lb
TRANSCEIVER UNIT
FS-5075T
27 kg
59.5 lb
HANDSET
HS-2003
0.5 kg
1.2 lb
FS-2575T
20 kg
44.1 lb
FS-1575T
16 kg
35.3 lb
AT-5075
8.5 kg
18.7 lb
AT-1575
2.6 kg
5.7 lb
47
1.85”
70
2.76
”
70
2.76”
100
3.94”
Ø8
400 15.75”
270 10.63”
4-Ø8
FIXING HOLE
491 19.33”
442 17.40” 412 16.22”
77
3.03”
55
2.17”
35
1.38”
200 7.87”