2. OPERATION
2-40
tensity. The brilliance of sea clutter is reduced to easily identify true targets from the
sea clutter.
Note 1:
Do not use the echo average function under heavy pitching and rolling. You
can lose a target.
Note 2:
This feature requires a heading signal and position data. When either signal
becomes lost, echo average is deactivated.
To correctly use the echo average function, first reduce the sea clutter:
1. Press the
MENU
key to open the menu.
2. Press
or
to select [Echo], then press the
ENTER
key.
3. Press
or
to select [Echo Average], then press the
ENTER
key.
4. Press
or
to select an echo averaging option, then press the
ENTER
key.
[
Off
]: Deactivate the echo average.
[
1
]: Identify true targets from the sea clutter and reduce the brilliance of unstable
echoes.
[
2
]: Identify true targets from the sea clutter that you cannot reduce the brilliance
with setting 1.
[
3
]: Identify true targets from the sea clutter that you cannot reduce the brilliance
with setting 1 or 2.
5. Press the
MENU
key to close the menu. The selected echo average ("EAV 1",
"EAV 2" or "EAV 3") appears at the lower-left corner of the display.
2.31
Display-Curve
You can change the characteristics curve to reduce unwanted weak echoes (sea re-
flections, etc.). Select [1], [2] or [3] depending on conditions when unwanted weak
echoes hide wanted targets.
1. Press the
MENU
key to open the menu.
2. Press
or
to select [Echo], then press the
ENTER
key.
Summary of Contents for FR-10
Page 1: ...OPERATOR S MANUAL www furuno com MARINE RADAR Model FR 10 FR 12 ...
Page 16: ...EQUIPMENT LIST xiv This page is intentionally left blank ...
Page 36: ...1 INSTALLATION WIRING 1 20 This page is intentionally left blank ...
Page 122: ...6 RADIO OPERATION 6 4 This page is intentionally left blank ...
Page 136: ...8 MAINTENANCE TROUBLESHOOTING 8 8 This page is intentionally left blank ...
Page 163: ...D 1 1 F eb 2 022 H M AKI ...
Page 164: ...D 2 1 Feb 2022 H MAKI ...
Page 165: ...D 3 1 Feb 2022 H MAKI ...
Page 166: ...D 4 1 Feb 2022 H MAKI ...