2. OPERATION
2-27
2.22.4
How to sleep a target alarm temporarily
When you do not require a target alarm temporarily, you can sleep the target alarm.
The alarm zone remains on the screen, but any targets that enter (or exit) the alarm
zone do not trigger the audio and visual alarms.
1. Press the
TARGET ALARM
key to select the ALARM 1 or ALARM 2 indication at
the upper-right corner on the screen. The selected indication is in a rectangle.
2. Press the
CANCEL/HL OFF
key. The alarm zone is now slept.
To reactivate a sleeping target alarm zone, press the
TARGET ALARM
key to select
the required alarm, then press the
ENTER
key.
2.22.5
How to deactivate a target alarm
1. Press the
TARGET ALARM
key to select the ALARM 1 or ALARM 2 indication at
the upper-right corner on the screen. The selected indication is in a rectangle.
2. Press the
MENU
key.
3. Press the
TARGET ALARM
key. The alarm indication is shown in a blue.
4. Press the
MENU
key. The target alarm zone and the alarm indication are erased
from the screen.
2.22.6
How to select the target strength which triggers a target alarm
You can select the target strength which triggers the target alarm as follows:
1. Press the
MENU
key to open the menu.
2. Press
or
to select [Alert Settings], then press the
ENTER
key.
3. Press
or
to select [Alarm Level], then press the
ENTER
key.
4. Press
or
to select the echo strength level, among [Low], [Middle] and [High].
5. Press the
ENTER
key followed by the
MENU
key.
2.22.7
How to turn the buzzer on/off
You can turn on/off the panel buzzer or external buzzer for target alarms. The panel
buzzer is for this equipment. The external buzzer is for the optional buzzer, which is
connected to this equipment to give the target alarm at a remote location.
1. Press the
MENU
key to open the menu.
2. Press
or
to select [Alert Settings], then press the
ENTER
key.
3. Press
or
to select [Panel Buzzer] (or [External Buzzer] for optional buzzer),
then press the
ENTER
key.
4. Press
or
to select [On] or [Off] then press the
ENTER
key.
5. Press the
MENU
key to close the menu.
Summary of Contents for FR-10
Page 1: ...OPERATOR S MANUAL www furuno com MARINE RADAR Model FR 10 FR 12 ...
Page 16: ...EQUIPMENT LIST xiv This page is intentionally left blank ...
Page 36: ...1 INSTALLATION WIRING 1 20 This page is intentionally left blank ...
Page 122: ...6 RADIO OPERATION 6 4 This page is intentionally left blank ...
Page 136: ...8 MAINTENANCE TROUBLESHOOTING 8 8 This page is intentionally left blank ...
Page 163: ...D 1 1 F eb 2 022 H M AKI ...
Page 164: ...D 2 1 Feb 2022 H MAKI ...
Page 165: ...D 3 1 Feb 2022 H MAKI ...
Page 166: ...D 4 1 Feb 2022 H MAKI ...