2. SYSTEM MENU
34
2.11
How to Set Up the FE-800 for Data Recording
The following setup procedure is required before using the optional data recording software.
1. Press the
MENU/ESC
key to open the Main menu.
2. Select [System] using
or
, then press the
ENT
key.
3. Select [Data Recorder] using
or
, then press the
ENT
key.
4. Select [DEST IP Address] using
or
, then press the
ENT
key. This will open a pop-up
window to set the IP address of the connected PC.
The available setting range is [000.000.000.000] to [255.255.255.255].
Note:
Do not use the following IP range: [239.192.000.001] to [239.192.000.064].
5. Press
to increase or
to reduce the value of the highlighted digit. Press
or
to select
a digit to set. To complete the setting process for the IP address, press
until the cursor
passes the final digit.
6. Select [DEST Port] using
or
, then press the
ENT
key. A pop-up window to set the
destination port on the connected PC appears.
The available setting range is [00000] to [65535].
7. Press
to increase or
to reduce the value of the highlighted digit. Press
or
to select
a digit to set. To complete the setting process for the Port, press
until the cursor passes the
final digit.
8. Press the
DISP
key to close the menu.
2.12
How to Set Draught from External Equipment
To use the draught value from external equipment, do the following:
1. Press the
MENU/ESC
key to open the Main menu.
2. Select [System] using
or
, then press the
ENT
key.
3. Select [EXT Setting] using
or
, then press the
ENT
key.
4. Select [ON]
or
, then press the
ENT
key.
5. Press the [DISP] to close the menu.