21
2.
SYSTEM MENU
The [System Menu] should be preset at installation. Normally, there is no need to access this
menu.
Note:
The echo display will be cleared when the [System Menu] is opened.
2.1
How to Set the Basic Range Scale
Use the table below for reference when changing the range scale settings. Depending on your
configuration, some options may not be available.
1. Press the
MENU/ESC
key to open the Main menu.
2. Select [System] using
or
, then press the
ENT
key.
3. Select [Range] using
or
, then press the
ENT
key. This will open a pop-up window.
4. Select the basic range scale using
or
, then press the
ENT
key. This will open a pop-up
window.
5. Adjust the range, if required, using
or
, then press the
ENT
key to apply the setting and
close the pop-up window.
To keep the default setting, press the
MENU/ESC
key or
.
6. Press the
MENU/ESC
key three times to close the menu.
Range scale setting
Range
Default
BASIC RANGE1
5 to (BR2-1)
5 m
BASIC RANGE2
(BR1+1) to 19
10 m
BASIC RANGE3
20
20 m
BASIC RANGE4
21 to (BR5-1)
40 m
BASIC RANGE5
(BR4+1) to 199
100 m
BASIC RANGE6
200
200 m
BASIC RANGE7
201 to (BR8-1)
400 m
BASIC RANGE8
(BR7+1) to 2400
800 m