25. MAINTENANCE AND TROUBLESHOOTING
25-3
25.2
How to Replace the Fuses
The fuse in the Power Supply Unit, Processor Unit, monitor unit and sensor adapter
protects those units from overvoltage (overcurrent) and internal fault. If a unit cannot
be turned on, check if its fuse has blown. If the fuse has blown, find out the cause be-
fore replacing the fuse. If the fuse blows again after replacement, contact your dealer
for advice.
3 to 6 months
Cabling
Check that all cabling is firmly
connected and is not dam-
aged.
Exposed bolts and
nuts of antenna unit
Exposed bolts and nuts are
subject to corrosion. Further,
they may loosen by vibration.
Check that bolts and nuts
are not corroded and are se-
curely fastened. If corroded,
clean and coat with anticor-
rosive sealant.
Radiator
Dust, dirt and salt deposits on
the radiator cause signal at-
tenuation, resulting in loss of
sensitivity. Wipe radiator with
a freshwater-moistened cloth.
The radiator is made of fiber-
glass reinforced plastic.
Therefore, do not used gas-
oline, benzene and the like
to clean the radiator.
If the radiator is iced, use a
wooden or plastic headed
hammer to remove the ice.
DO NOT use a steel ham-
mer.
Terminals, connec-
tors
Check that all terminals and
connectors on circuit boards
are securely fastened.
Have a qualified technician
check terminals and connec-
tors.
6 months to 1
year
Screws on terminal
boards in Proces-
sor Units
Check that all screws are
tightly fastened.
Have a qualified technician
check screws.
Unit
Power supply
Type
Code no.
Power Supply Unit PSU-014
100-230 VAC
F1: FGBO 250V 7A PBF
000-178-084-10
Power Supply Unit PSU-015
100-230 VAC
F1: FGBO 250V 3A PBF
F2: FGBO 250V 7A PBF
000-155-841-10
000-178-084-10
Power Supply Unit PSU-016
100-230 VAC
F1: FGBO 250V 5A PBF
000-155-840-10
Power Supply Unit PSU-018
100-230 VAC
F1: FGBO 250V 3A PBF
F2: FGBO 250V 7A PBF
000-155-841-10
000-178-084-10
Monitor Unit MU-190
100-230 VAC
FGBO 250V 1A PBF
000-155-828-10
Monitor Unit MU-231
100-230 VAC
FGBO 250V 1.5A PBF
000-155-833-10
Processor Unit EC-3000
100-115 VAC
FGMB 125V 10A PBF
000-157-470-10
220-230 VAC
FGMB 250V 5A PBF
000-157-570-10
Sensor Adapter MC-3000S
24 VDC
FGMB 125V 3A PBF
000-157-481-10
Interval
Check point
Check and measures
Remarks
Use the proper fuse.
Use of a wrong fuse can damage the
equipment or cause fire.
WARNING
Summary of Contents for FCR-2119-BB
Page 66: ...1 OPERATIONAL OVERVIEW 1 40 This page is intentionally left blank ...
Page 134: ...2 RADAR CHART RADAR OPERATION 2 68 This page is intentionally left blank ...
Page 182: ...4 AIS OPERATION 4 22 This page is intentionally left blank ...
Page 198: ...5 RADAR MAP AND TRACK 5 16 This page is intentionally left blank ...
Page 290: ...9 VECTOR S57 CHARTS 9 12 This page is intentionally left blank ...
Page 296: ...10 C MAP CHARTS 10 6 This page is intentionally left blank ...
Page 392: ...16 NAVIGATION SENSORS 16 16 This page is intentionally left blank ...
Page 398: ...17 AIS SAFETY NAVTEX MESSAGES 17 6 This page is intentionally left blank ...
Page 466: ...24 CONNING DISPLAYS 24 4 Example 2 General navigation Example 3 General navigation ...
Page 467: ...24 CONNING DISPLAYS 24 5 Example 4 General navigation Example 5 All waters navigation Silence ...
Page 534: ...FURUNO FCR 21x9 BB FCR 28x9 SERIES SP 6 E3607S01D M This page is intentionally left blank ...
Page 541: ......