1. MOUNTING
3
1.2
LAN Cable Fabrication
Fabricate the LAN cable (MOD-Z072-050 (5 m), supplied as installation materials) be-
tween the communication unit and cradle (IP handset) as follows. The optional FR-
FTPC-CY cable (10, 20, 30 or 50 m) is available for the IP handset.
Note:
This equipment can use either straight or crossover cables.
Expose inner vinyl sheath.
Remove the inner vinyl sheath by
approx. 25 mm. Be careful not to
damage inner shield and cores.
Fold back the shield, wrap it onto
the inner vinyl sheath and cut it,
leaving approx. 9 mm.
25 mm
approx. 9 mm
approx. 9 mm
approx. 11 mm
Fold back drain wire and cut it,
leaving approx. 9 mm.
Straighten and flatten the cores
in colored order and cut them,
leaving approx. 11 mm.
Modular plug
Using special crimping tool
MPT5-8AS (PANDUIT CORP.), crimp
the modular plug. Finally, check the
plug visually.
Insert the cable into the modular
plug so that the folded part of the
shield enters into the plug housing.
The drain wire should be located
on the tab side of the jack.
Drain wire
1 WHT/GRN
2 GRN
3 WHT/ORG
4 BLU
5 WHT/BLU
6 ORG
7 WHT/BRN
8 BRN
WHT/ORG 1
ORG 2
WHT/GRN 3
BLU 4
WHT/BLU 5
GRN 6
WHT/BRN 7
BRN 8
[Crossover cable]
1 WHT/ORG
2 ORG
3 WHT/GRN
4 BLU
5 WHT/BLU
6 GRN
7 WHT/BRN
8 BRN
WHT/ORG 1
ORG 2
WHT/GRN 3
BLU 4
WHT/BLU 5
GRN 6
WHT/BRN 7
BRN 8
[Straight cable]
150
䡉䡉
(Communication unit side)
200 mm (IP handset side)
150
䡉䡉
(Communication unit side)
200 mm (IP handset side)
Cable jacket
Armor
Inner vinyl sheath
Outer vinyl sheath
Vinyl tape
Summary of Contents for FB-8001
Page 10: ...D 1 20 Mar 2019 H MAKI ...
Page 11: ......