1
1.
MOUNTING
1.1
IP Handset
The IP Handset functions as a display and it may also be used for normal voice com-
munication. A maximum of 16 units can be installed anywhere onboard the vessel.
The IP Handset is provided with a cradle assembly (chassis cradle and cradle). The
assembly is designed for both bulkhead and desktop installations, with cable entries
for both methods.
1. To use the rear cable entry, make a hole of 18 mm (0.71") diameter in the instal-
lation site. See the outline drawing at the rear of this manual for details.
2. Install the chassis cradle with three self-tapping screws (3
20).
3. Connect the curled cord from the IP Handset to the RJ-45 port indicated in the
above figure.
Note:
To avoid possible faults in the IP Handset, do not plug or unplug the hand-
set while the Communication Unit or PoE hub (local supply) are turned on.
4. Secure the curled cord with a cable tie (supplied).
Do not apply paint, anti-corrosive sealant or contact
spray to coating or plastic parts of the equipment.
Those items contain organic solvents that can damage
coating and plastic parts, especially plastic connectors.
NOTICE
: Screw holes,
3 places × ø4.6
Chassis
cradle
RJ-45 port for
IP Handset
RJ-45 port for
Communication
Unit
Cable tie
Curled cord from IP Handset