background image

i

 

SAFETY INSTRUCTIONS

Do not open the equipment unless 
totally familiar with electrical circuits 
and service manual.

Only qualified personnel should work 
inside the equipment.

Turn off the power at the mains 
switchboard before beginning the 
installation. Post a sign near the 
switch to indicate it should not be 
turned on while the equipment is 
being installed.

Fire, electrical shock or serious injury 
can result if thepower is left on or is 
applied while the eqiuipment is being
installed.

WARNING

Indicates a condition that can cause death or serious injury if
not avoided.

CAUTION

Indicates a condition that can cause minor or moderate injury if
not avoided. 

 Mandatory Action

 

Prohibitive Action

Read these safety instructions before you operate the equipment. 

Warning, Caution

WARNING

WARNING

Confirm that the power supply voltage
 is compatible with the voltage rating 
of the equipment.

Connection to the wrong power supply 
can cause fire or damage the equipment. 

Keep the following compass safe 
distances to prevent interference to 
a magnetic compass.

1.60 m

2.40 m

IP Handset

Unit

Standard
Compass

Steering
Compass

Summary of Contents for FB-8001

Page 1: ...trademarks or service marks of their respective holders Installation Manual IP HANDSET Model FB 8001 SAFETY INSTRUCTIONS i SYSTEM CONFIGURATION ii 1 MOUNTING 1 1 1 IP Handset 1 1 2 LAN Cable Fabrication 3 2 SETTING UP THE EQUIPMENT 4 PACKING LIST A 1 OUTLINE DRAWINGS D 1 ...

Page 2: ...he eqiuipment is being installed WARNING Indicates a condition that can cause death or serious injury if not avoided CAUTION Indicates a condition that can cause minor or moderate injury if not avoided Mandatory Action Prohibitive Action Read these safety instructions before you operate the equipment Warning Caution WARNING WARNING Confirm that the power supply voltage is compatible with the volta...

Page 3: ...cted from the weather AC DC Power Supply Unit 406080A FUR 001 100 240V AC 12 24V DC IP Handset FB 8001 Alarm Panel FB 3101 Network Equipment IP Handset Network Equipment IP Handset GS Facsimile or Analog Telephone GS Facsimile or Analog Telephone GS Facsimile or Analog Telephone Up to 4 connections External Alarm Communication Unit FB 2001 Relay AY34001 Cradle PC USB RS232C Converter FB 3003 Telpo...

Page 4: ...ils 2 Install the chassis cradle with three self tapping screws 3 20 3 Connect the curled cord from the IP Handset to the RJ 45 port indicated in the above figure Note To avoid possible faults in the IP Handset do not plug or unplug the hand set while the Communication Unit or PoE hub local supply are turned on 4 Secure the curled cord with a cable tie supplied Do not apply paint anti corrosive se...

Page 5: ... secure the LAN cable with a cable tie supplied Note For how to fabricate the LAN cable see section 1 2 6 Fit the cradle to the chassis cradle fit the supplied nylon washers to the four self tapping screws 4 40 then secure the cradle in place with the self tapping screws Cable tie Cable from Communication Unit From bottom From rear Cable from Communication Unit Screw holes 4 places ø4 7 ...

Page 6: ...ten and flatten the cores in colored order and cut them leaving approx 11 mm Modular plug Using special crimping tool MPT5 8AS PANDUIT CORP crimp the modular plug Finally check the plug visually Insert the cable into the modular plug so that the folded part of the shield enters into the plug housing The drain wire should be located on the tab side of the jack Drain wire 1 WHT GRN 2 GRN 3 WHT ORG 4...

Page 7: ...ING UP THE EQUIPMENT Set up the FELCOM251 501 from the Web interface and IP handset user menu after the installation For details of the Web interface and IP handset user menu see the operator s manual OME 57050 ...

Page 8: ...TALLATION MATERIALS 工事材料 INSTALLATION MATERIALS CP16 06801 001 537 170 00 1 図書 DOCUMENT 取扱説明CD OPERATOR S MANUAL CD F251 501 O M CDROM 000 195 892 1 1 操作要領書 OPERATOR S GUIDE JP EN OSC 57050 000 195 882 1 1 装備要領書 INSTALLATION MANUAL IM 57050 000 195 884 1 1 コード末尾に の付いたユニットは代表の型式 コードを表示しています CODE NUMBER ENDING WITH INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL 略図の寸法は 参考値です DIMENSIONS IN DRA...

Page 9: ...EMBLY CP16 06802 1 001 546 060 00 1 CODE NO トラスタッピンネジ SELF TAPPING SCREW 3X20 SUS304 3 000 167 940 10 2 CODE NO トラスタッピンネジ SELF TAPPING SCREW 4X40 SUS304 4 000 162 606 10 3 CODE NO コンベックス CABLE TIE CV 125N 2 000 172 164 10 4 CODE NO 黒ナイロンワッシャ NYLON WASHER NN 0408 05B 4 000 195 852 10 5 CODE NO 略図の寸法は 参考値です DIMENSIONS IN DRAWING FOR REFERENCE ONLY FURUNO ELECTRIC CO LTD C5705 M03 A A 2 ...

Page 10: ...D 1 20 Mar 2019 H MAKI ...

Page 11: ......

Page 12: ...his manual is elemental chlorine free FURUNO Authorized Distributor Dealer 9 52 Ashihara cho Nishinomiya 662 8580 JAPAN A MAR 2019 Printed in Japan All rights reserved Pub No IME 57050 A GREG FB 8001 0 0 0 1 9 5 8 8 4 1 0 ...

Reviews: