Furuno FB-3101 Operator'S Manual Download Page 1

www.furuno.com

ALARM PANEL

OPERATOR'S MANUAL

Model

アラームパネル

取扱説明書

FB-3101

Summary of Contents for FB-3101

Page 1: ...www furuno com ALARM PANEL OPERATOR S MANUAL Model FB 3101...

Page 2: ......

Page 3: ...r service marks of their re spective holders How to discard this product Discard this product according to local regulations for the disposal of industrial waste For disposal in the USA see the homepa...

Page 4: ...IRCUITS Operating personnel must not remove equipment covers Component replacement and internal adjustment must be made by qualified maintenance personnel Do not service the unit with the power cable...

Page 5: ...AYDAY MAYDAY This is NAME NAME NAME CALLSIGN or other IDENTIFICATION MMSI MAYDAY NAME of the VESSEL in distress CALLSIGN or other IDENTIFICATION MMSI POSITION given as latitude and longitude or If lat...

Page 6: ...Handset 5 2 2 2 In Alarm Panel 5 3 USING THE SYSTEM 6 3 1 Making a Distress Call 6 3 2 Making an Urgency Call 32 38 39 7 3 3 Receiving Distress Calls 9 3 4 Displaying Faults 10 3 5 General Functions...

Page 7: ...e are confident you will see why FURUNO has become synonymous with quality and reliability Your equipment is designed and constructed to meet the rigorous demands of the marine envi ronment However no...

Page 8: ...ted from the weather AC DC Power Supply Unit 406080A FUR 001 100 240V AC 12 24V DC IP Handset FB 8001 Alarm Panel FB 3101 Network Equipment IP Handset Network Equipment IP Handset GS Facsimile or Anal...

Page 9: ...system and an IP Handset designated for Distress use 1 1 1 System components The system includes the following system components Alarm Panel FB 3101 IP Handset FB 8001 Communication Unit FB 2001 Ante...

Page 10: ...hich is designated for Safety Voice is also able to function as a normal IP Hand set Additional IP Handsets may be used for normal voice communication non Distress 1 1 3 FleetBroadband system Communic...

Page 11: ...until a new event activates the buzzer again 3 Dim Increases the light in the display 4 Dim Dims the light in the display 5 FB Distress Initiates a Distress call to the nearest Maritime Rescue Co ord...

Page 12: ...iority call ac cess interrupting all non distress calls as soon as the red distress button is pushed When the red distress button on the Alarm Panel is pushed during an emergency the service will inte...

Page 13: ...talled For information on how to insert the SIM card refer to the Installation Manual IMC 57060 for the FELCOM251 FELCOM501 2 2 Checking the System Note Before you can use the Safety Voice functions t...

Page 14: ...he Alarm Panel Configuring the system for Safety Voice Testing the Safety Voice Non SOLAS system 3 1 Making a Distress Call Before you can make a Distress call the system must be configured for Safety...

Page 15: ...1 Urgency calling is an INMARSAT service and is not GMDSS compliant Note 2 Urgency calling requires a Safety Voice contract available through your service provider Note 3 You can only make an urgency...

Page 16: ...dset is not a Safety Voice Handset the following menu is not displayed The Safety Voice Handset has the icon in its status bar 4 Press or to select Medical Advice Medical Assist or Maritime Assist men...

Page 17: ...aged in a Distress call when receiving an incoming Distress call you will hear a Call Waiting tone and you can accept or ignore the second call If there was an ongoing lower priority call you will hea...

Page 18: ...sappears and FB and Fault are flashing If the Fault indicator is shown you can check the list of active events in the IP Handset as follows 1 From the IP Handset press the Enter key to open the main m...

Page 19: ...ng the FB Distress but ton The buzzer starts to sound intermittently with increasing strength to indicate that the pushed button and the buzzer is working Muting the alarm sound To mute the alarm soun...

Page 20: ...is pressed You can always use the Dim buttons to dim the light again if you want to 3 6 Configuring the System for Safety Voice To configure the system for Safety Voice consult your local dealer 3 7 T...

Page 21: ...he IP Handset for Safety Voice can show warnings and display a list of active events in the total FleetBroadband system To see the list of events press the Enter key and select Notifica tions For a li...

Page 22: ...that Call Waiting service is commissioned 0x10501 Safety voice handset is not connected Check if Safety Voice handset is con nected correctly to the LAN PoE inter face If it is connected correctly pl...

Page 23: ...nge when enabled disabled in the web interface of the Communication Unit 3 Consult your dealer 4 The SIM card for your Com munication Unit is not commis sioned for Safety Voice eMLPP 4 Check your airt...

Page 24: ...P Handset or in the connection to the handset 2 Check the connection to the handset If possible press the Enter key and select Notifica tions in the IP Handset to see the error If not possible con nec...

Page 25: ...of any warranty issue 4 4 1 Repacking for shipment Should you need to send the product for repair please read the below information before packing the product The shipping carton has been carefully de...

Page 26: ...raphic area and lack of a need for leased telecommunication lines LED Light Emitting Diode MMSI Maritime Mobile Service Identity A series of nine digits which are sent in digital form over a radio fre...

Page 27: ...tress button 12 Features 1 FleetBroadband system configuring 13 description 2 Functions in Alarm Panel 12 G Getting started 5 I IP Handset description 2 emergency call 7 urgency call 8 L LEDs in Commu...

Page 28: ......

Page 29: ...i...

Page 30: ...ii FB Distress FB Distress MRCC Maritime Rescue Coordination Centre...

Page 31: ...iii...

Page 32: ...LAS 1 1 1 1 1 1 1 2 2 1 1 3 2 1 1 4 3 1 2 SOLAS 4 2 5 2 1 5 2 2 5 2 2 1 5 2 2 2 5 3 6 3 1 6 3 2 32 38 39 7 3 3 9 3 4 10 3 5 11 3 6 12 3 7 SOLAS 12 4 13 4 1 13 4 1 1 13 4 1 2 13 4 2 14 4 3 15 4 4 16 4...

Page 33: ...v 1948...

Page 34: ...vi...

Page 35: ...1 1 SOLAS SOLAS SOLAS 1 1 SOLAS SOLAS FELCOM251 FELCOM501 1 1 1 FB 3101 FB 8001 FB 2001 FB 1251 FB 1501 FELCOM251 FELCOM501 IMC 57060...

Page 36: ...1 2 1 1 2 FB Distress MRCC Maritime Rescue Coordination Centre 1 1 3 SOLAS eMLPP eMLPP LAN SOLAS LAN...

Page 37: ...1 3 1 1 4 Test Mute Dim Dim FB Distress MRCC Maritime Rescue Coordination Centre FB 2 2 2 Distress Fault Test FB Distress Fault Test...

Page 38: ...1 4 3 11 1 2 SOLAS SOLAS eMLPP FB Distress eMLPP FB Distress MRCC Maritime Rescue Coordination Centre www inmarsat com...

Page 39: ...5 2 SIM FELCOM251 FELCOM501 IMC 57060 2 1 SOLAS SIM eMLPP SIM SIM FELCOM251 FELCOM501 IMC 57060 2 2 2 2 1 2 2 2 FB Fault...

Page 40: ...6 3 FELCOM251 FELCOM501 OMJ 57050 SOLAS 3 1 FB 1 FB Distress 2 FB Distress 6...

Page 41: ...3 7 3 MRCC iii Distress 3 2 32 38 39 2 32 38 39 1 32 38 39 GMDSS 2 32 38 39 3 32 38 39 32 38 39 2 32 38 39 FB Distress...

Page 42: ...3 8 1 32 38 39 2 1 1 2 3 Rescue Call 4 Medical Advice Medical Assist Maritime Assist 5 Call 32 Call 38 Call 39...

Page 43: ...3 9 3 3 Distress Distress FB Distress...

Page 44: ...3 10 3 4 Fault Fault FB FB Fault Fault 1 2 Notifications Web FELCOM251 FELCOM501 OMJ 57050 FB Fault...

Page 45: ...3 11 3 5 FB Distress Test Mute Dim Dim FB Distress 3 1 FB Distress Test LED 1 Test FB Distress 2 Test FB Distress FB Distress 1 2 2 Mute Mute FB Distress FB Distress 20 20...

Page 46: ...3 12 Mute Dim Dim Dim Dim Test 3 6 3 7 SOLAS 3 11...

Page 47: ...13 4 4 1 4 1 1 4 1 2 Notifications FELCOM251 FELCOM501 OMJ 57050 FB FB Fault Distress Test...

Page 48: ...enabled or it has taken too long time in total 5 minutes SIM eMLPP 0x10501 Safety voice handset is not connected LAN PoE 0x10502 Safety voice settings are changed 0x10503 Safety voice settings are ch...

Page 49: ...15 4 3 1 1 PC Web SETTINGS IP Handsets Admin Telephony Settings Phone List Ready 2 2 3 3 4 SIM eMLPP 4 eMLPP BGAN 1 PIN 1 PIN 2 BGAN 2 FELCOM251 FELCOM501 OMJ 57050 1 1 2 2 FELCOM251 FELCOM501 OMJ 570...

Page 50: ...4 16 4 4 4 4 1 Fault 1 1 Web 2 2 Notifications Web 3 BGAN 3 SIM 4 4...

Page 51: ...P Internet Protocol LAN Local Area Network LAN WAN Wide Area Network LED Leght Emitting Diode MMSI Maritime Mobile Service Identity 9 MRCC Maritime Rescue Coordination Centre Non SOLAS Not covered by...

Page 52: ...IN 1 D Dim 12 F FB Distress 11 M Mute 12 T Test 11 3 3 11 3 4 3 11 11 14 13 12 32 38 39 7 7 14 16 SOLAS 4 5 16 10 1 5 16 13 SOLAS 1 4 5 1 12 9 12 6 12 12 15 2...

Page 53: ...IN 2 3 4 11 12 2 12 16 16 16 Dim 12 FB Distress 11 Mute 12 Test 11 3 7 6 9...

Page 54: ......

Page 55: ......

Page 56: ...EG FB 3101 Pub No OMC 57051 A1 Printed in Japan Elemental Chlorine Free The paper used in this manual is elemental chlorine free FURUNO Authorized Distributor Dealer MAR 2019 JUN 07 2019 A A1 00019588...

Reviews: