7. MAINTENANCE, TROUBLESHOOTING
7-12
5. Insert the USB flash memory to the USB port.
The indicator changed from “NO USB” to “SAVING st-by”.
6. Press the
left button
to start saving the log.
The indicator changes to “SAVING”.
7. Press the
left button
to stop the saving process.
8. Remove the USB flash memory from the port.
9. Press the
GO TO
key to display CANbus connected device informations.
To change the page, press
MARK SELECT
or
MARK
key.
10. Select a device, then press the
left button
.
The details for the device selected are shown.
11. To set a device as the main heading sensor, select the device, then press the GO
TO key. A
ۍ
mark appears in the [SET] column for the main sensor. Other sen-
sors which are also used show a
ۍ
mark in the [USE] column.
12. Press the
right button
to close the menu.
7.9
Operation/ Alert Log
You can check the operation and alert log from the log monitor
1. Open the [MAIN MENU].
2. Select [INITIAL SETTING], then press the
left button
.
3. Select [MAINTENANCE], then press the
left button
.
4. Select [OPERATION/ALERT LOG], then press the
left button
.
Press [MARK SELECT] or [MARK] button to change the pages.
5. Press the
right button
to close the menu.
[MARK SELECT] : PREVIOUS PAGE [MARK] : NEXT PAGE
PRESS LEFT BUTTON : SHOW DETAILS
[GO TO] : SET AS MAIN HEADING SENSOR
CANbus CONNECTION DEVICE DISPLAY
PAGE _ 1/1
SA SET USE Model ID
Serial Code
LEN
1 SC-60
12345-67890
3
2 SC-30
96765-43210
5
LEN (ALL) : 8
Summary of Contents for FAR-1416
Page 90: ...2 RADAR OBSERVATION 2 8 This page is intentionally left blank ...
Page 116: ...4 AIS OPERATION 4 10 This page is intentionally left blank ...
Page 172: ...5 VIDEO PLOTTER OPERATION 5 56 This page is intentionally left blank ...
Page 186: ...6 DATA SAVE AND READ 6 14 This page is intentionally left blank ...
Page 222: ...FURUNO FAR 1416 1426 SP 4 E3650S01D M This page is intentionally left blank ...