background image

UAIS TRANSPONDER FA-100 

Operator’s Guide 

The purpose of this Operator's Guide is to provide basic operating procedures for this equipment. For 
more detailed information see the Operator's Manual. 
 

Turning on and off 

·

 

Press POWER key. 

After self-test, the plotter display appears. 

[- - - - - -]
SOG:
- - -.- kt
COG:
- - -.-  deg
INTRD: 0
[

    

]: FWD

[  

  

]: BACK

   RNG:    1.50 

n
m

 

Adjusting brilliance and contrast 

1.  Press CLR/ALT and SFT keys together. 

BRILLIANCE 

CONTRAST

ESC: [ENT]

 

2. Press 

 or 

 to adjust brilliance; 

or 

 to 

adjust contrast. 

3. Press 

ENT 

key. 

Setting up for a voyage 

Enter at the start of a voyage: draught, 
destination, navigation, status, etc. 
1.  Press MENU, [5], and [1] key in that order. 

+ -

123

[SET SHIP DATA]         

   DRAUGHT: 07.5 m
   DTE

: KEY & DISP

            

 

2.  DRAUGHT is selected; enter ship's current 

draught. 

3.  Press ENT, and then [2] key. 

[SET DESTINATION]

DATE:

0

0/00  (DD/MM)

    TIME: 00:00

DESTINATION:

NONE

 

4.  Press NEXT to choose DATE, TIME or 

DESTINATION and enter estimated date/time 
of arrival or destination waypoint. 

5.  Press ENT, and then [3] key. 

STATUS NAME

[SET STATUS]          

  

    

       
    NAV STATUS: 00     

  

 

UNDER WAY USING
ENGINE (DEFAULT)

 

 
6. Press 

 or 

 key to choose 

appropriate navigation status. 

7.  Press ENT, and then [4] key. 

TYPE NAME

[SET TYPE&CREW]         

    CREW            : 0012
    TYPE CLASS : A       
    TYPE NO.      :     0     

 

 

+ -

 

8.  CREW is selected; enter number of crews. 
9.  Press NEXT to choose TYPE NO. and press 

arrow keys to choose appropriate type 
number. 

 

: Increment, decrement by 1 

 

: Increment, decrement by 10 

10. Press ENT and MENU in that order. 

SAVE ?

YES

    NO

CANCEL

 

11. YES is selected; enter ENT. 

Setting CPA/TCPA 

1.  Press MENU, [5], and [5] key in that order. 

[SET CPA/TCPA]

CPA:

0

.90 nm

   TCPA: 

   01 min

   ACTV:

DSBL      

+ -

 

2.  Enter CPA and press NEXT. 
3.  Enter TCPA and press NEXT. 
4.  Press SFT to choose ENBL to activate the 

CPA/TCPA alarm; DSBL to disable it. 

5.  Press ENT, MENU and ENT in that order. 

Enabling/Disabling buzzer 

1.  Press MENU, [6] and [5] key in that order. 

[SET BUZZER]
    ALARM

: ON

    CPA/TCPA : ON
    MSG ALM : ON       
         

+ -

+ -

+ -

 

2.  Press SFT to choose ON or OFF for each item. 

ALARM: for system trouble 

CPA/TCPA: for CPA/TCPA alarm 

MSG ALM: for incoming message 

Reviews: