2. WIRING
2-5
2.2
DIPSW S3 Settings
DIPSW S3 is on the MAIN Board (66P3950) inside the Distribution Unit DS-610.
S3-#1,2
Set the S3-#1 and S3-#2 according to the speed scale range of the analog indicator.
These settings do not affect the analog output (voltage, current).
Note:
These settings are for the analog displays 1 and 2.
S3-#4 to #8
Alarm contact input/output settings by the DIPSW S3 are shown below.
Note 1:
S3-#3 should remain OFF, the default setting.
Note 2:
[POWER FAIL] is normal close output regardless of the settings of DIPSW.
When the power is off, all contact outputs are open output.
-10 to 20 kn
-10 to 30 kn
-10 to 40 kn
S3-#1
OFF
OFF (Default)
ON
S3-#2
ON
OFF (Default)
OFF
OFF (Default settings)
ON
S3-#4
REMOTE ACK
Contact input
For ACK, close input
Contact input
For ACK, open input
S3-#5
LOCAL ACK
Contact output
For ACK, close output
Contact output
For ACK, open output
S3-#6
ECHO FAIL
Contact output
Normal open output
Contact output
Normal close output
S3-#7
SPEED LIMIT
Contact output
Normal open output
Contact output
Normal close output
S3-#8
SYSTEM FAIL
Contact output
Normal open output
Contact output
Normal close output
MAIN Board (66P3950)
ON
OFF
DIPSW S3
Distribution Unit DS-610, cover removed
Summary of Contents for DS-60
Page 51: ...APPENDIX 1 CALIBRATION AP 3 ...
Page 59: ...8 Mar 2010 Y NISHIYAMA D 1 ...
Page 60: ...18 Dec 2012 Y NISHIYAMA D 2 ...
Page 61: ...18 Dec 2012 Y NISHIYAMA D 3 ...
Page 62: ...D 4 30 Jun 2015 H MAKI ...
Page 63: ...D 5 30 Jun 2015 H MAKI ...
Page 64: ...1 Jul 2011 Y NISHIYAMA D 6 ...
Page 65: ...29 Mar 2011 Y NISHIYAMA D 7 ...
Page 66: ...29 Mar 2011 Y NISHIYAMA D 8 ...
Page 67: ...D 9 30 Jun 2015 H MAKI ...
Page 68: ...D 10 30 Jun 2015 H MAKI ...
Page 69: ...D 11 15 Apr 2016 H MAKI ...
Page 70: ...D 12 15 Apr 2016 H MAKI ...
Page 71: ...D 13 15 Apr 2016 H MAKI ...
Page 72: ...D 14 15 May 2015 H MAKI ...