Chapter 2: Installation
11
This connector is used when adding a 406080A-FUR AC/DC Power
Supply Unit (dual row spring loaded terminal).
3. In order to be able to daisy-chain up to three 406080A-FUR AC/DC
Power Supply Units the
Mains AC
connector has two terminals:
• Use one terminal for the incoming mains power.
• Use the other terminal for the mains power going to the next
406080A-FUR AC/DC Power Supply Unit.
DC output
The 406080A-FUR AC/DC Power Supply Unit supplies a DC output. To
connect the DC output
DC1
do as follows:
1. Connect the DC cable to the connector marked
DC1
and the
equipment that must be powered.
AC input
To connect to additional
AC/DC Power Supply
DC 1
Connector type
Spring-loaded terminal
Wire cross
section
Up to 6 mm
2
Maximum load
30 A
+
DC out, plus
-
DC out, minus
GND
Summary of Contents for 406080A-FUR
Page 1: ...AC DC POWER SUPPLY UNIT 406080A FUR OPERATOR S MANUAL www furuno com Model...
Page 2: ......
Page 8: ...Table of contents vi Packing lists PL 1...
Page 26: ...Chapter 2 Installation 18 This page is intentionally left blank...
Page 36: ...Appendix C Special installation 28 This page is intentionally left blank...
Page 37: ...29 Appendix D Declaration of conformity D D 1 OEM declaration...