Before you get started:

• Make sure all optical ends

are clean to avoid poor in-
sertion loss readings and
prevent contamination of
the optical ports on the test
units.

• Annual calibration is

 recommended.

CAUTION: 

Never look directly into the
output ports of the light
source or the ends of a fiber
optic connector. The light may
not always be visible, but can
still cause damage to the eye.

• Turn 

on

LIGHT SOURCE

by

pulling up on the 

TOGGLE

SWITCH

and moving it to

the left or the right, select-
ing appropriate wavelength. 

NOTE:

To turn 

off 

light source, pull

up on toggle switch and move
to center position.

• Insert 

ST

®

CONNECTOR

end of 

LAUNCH JUMPER

into appropriate wavelength
port on Light Source.

• Insert other connector end of

Launch Jumper into Adapter
Cap on Power Meter.

• 

Zero

the Power Meter by

pressing and holding down
the 

Ref

button until 

HELD

and 

0.0 dB

is displayed. 

NOTE: 

It is recommended to 

re-zero

the Power Meter at least every
30 minutes.

• Disconnect connector end

of Launch Jumper from
adapter cap on Power
Meter and insert into

SPLICE BUSHING.

• Insert one connector end of

the 

DEVICE UNDER TEST

(DUT)

into the Splice Bush-

ing.

• Insert the other connector

end of the DUT into the
Adapter Cap on the Power
Meter.

• The number on the Power

Meter display represents the
insertion loss due to the
connector at the Splice
Bushing plus the attenuation
through the length of cable.

• Turn 

on

POWER METER

by

pressing      button. 

NOTE: 

To disable the 5-minute,
 automatic-shutdown battery
saver feature, hold down the
button      until 

P

is displayed.

• On the Power Meter press

the 

dB/dBm

button until 

dB

is displayed.

• On Power Meter press “

λ

"

button until appropriate
wavelength is displayed. 

• Install appropriate

ADAPTER CAP

onto Power

Meter.

• Allow 2 minutes for test set

to stabilize.

Technical Support 

888.438.9936

|   

www.ofsoptics.com

Test Kit

Quick Start Guide

(Procedure illustrates insertion loss by single-ended test method.  Refer to booklet for loss by substitution method.)

Before you get started:

• Make sure all optical ends

are clean to avoid poor in-
sertion loss readings and
prevent contamination of
the optical ports on the test
units.

• Annual calibration is

 recommended.

CAUTION: 

Never look directly into the
output ports of the light
source or the ends of a fiber
optic connector. The light may
not always be visible, but can
still cause damage to the eye.

• Turn 

on

LIGHT SOURCE

by

pulling up on the 

TOGGLE

SWITCH

and moving it to

the left or the right, select-
ing appropriate wavelength. 

NOTE:

To turn 

off 

light source, pull

up on toggle switch and move
to center position.

• Insert 

ST

®

CONNECTOR

end of 

LAUNCH JUMPER

into appropriate wavelength
port on Light Source.

• Insert other connector end of

Launch Jumper into Adapter
Cap on Power Meter.

• 

Zero

the Power Meter by

pressing and holding down
the 

Ref

button until 

HELD

and 

0.0 dB

is displayed. 

NOTE: 

It is recommended to 

re-zero

the Power Meter at least every
30 minutes.

• Disconnect connector end

of Launch Jumper from
adapter cap on Power
Meter and insert into

SPLICE BUSHING.

• Insert one connector end of

the 

DEVICE UNDER TEST

(DUT)

into the Splice Bush-

ing.

• Insert the other connector

end of the DUT into the
Adapter Cap on the Power
Meter.

• The number on the Power

Meter display represents the
insertion loss due to the
connector at the Splice
Bushing plus the attenuation
through the length of cable.

• Turn 

on

POWER METER

by

pressing      button. 

NOTE: 

To disable the 5-minute,
 automatic-shutdown battery
saver feature, hold down the
button      until 

P

is displayed.

• On the Power Meter press

the 

dB/dBm

button until 

dB

is displayed.

• On Power Meter press “

λ

"

button until appropriate
wavelength is displayed. 

• Install appropriate

ADAPTER CAP

onto Power

Meter.

• Allow 2 minutes for test set

to stabilize.

Technical Support 

888.438.9936

|   

www.ofsoptics.com

Test Kit

Quick Start Guide

(Procedure illustrates insertion loss by single-ended test method.  Refer to booklet for loss by substitution method.)