Technical Information Brochure
Universal DECT Secury System
10.05.2012
Alarms
Functional Description of UDSS
14
1.7.3 Login and log-off in the secure Secury mode
Directly after removing the FC4 U device from the desk-top charger, the user is
required to test all active (as enabled by the programming of the device) security
sensors. If required by the customer, the commencement of the start-up test can also
be carried out manually by means of an appropriate menu. Only after the successful
completion of the start-up test will the device automatically login to the UDSS server.
This test process is performed each time the device is taken into service or at least
once every 24 hours. The cyclic monitoring of the connection between the handset
and the UDSS server now begins. During this monitoring, the handsets are conti-
nuously tested for device faults. If a device develops a fault or reports a communica-
tion failure, then this information is reported immediately.
Log-off occurs automatically when the device is placed in the desk-top charger.
Cyclic monitoring of this FC4 device then ceases. As with login, log-off can also be
performed manually by means of a menu selection. Cyclic monitoring of this FC4 U
device then ceases. As with login, log-off can also be performed manually by means
of a menu selection.
PLEASE NOTE
Automatic testing of individual sensors and automatic login can also be switched off,
if the customer so requires.