Programming Guide
Register Function
00
Vref for Squelch detection leveö (Factory default --> 0x0A = 280 mV)
01
Vref for Squelch turn off level (Factory --> 0x06 = 140 mV)
02
Number of consecutive slopes onf start of Squelch
A break of 3.6 ms without slope resets the counter
Fectory default --> 0x05 = 6 slopes without break longer than 3,6 ms is detected as
Squelch
03
Follow-up time for Squelch detection x 10 ms
Factory default --> 0x50 = 50 x 10 ms = 500 ms
04
Locking time past PTT for Squelch detection x 10 ms
Factory default --> 0x10 = 10 x 10 ms = 100 ms
05
TX-Mode Low-Nibble
--> Pilotton bei TX
1 = an, 0 = aus
High-Nibble --> Relais bei TX
0 = TX-Relais on for TX, RX-Relais on for RX
1 = TX-Relais always on, RX-Relais on for RX - default
2 = TX-Relais an bei TX, RX-Relais immer an
3 = TX-Relais immer an, RX-Relais immer an
Factory default --> 0x11 = Relais and pilot tone on for TX
Register description EEPROM LIM-AC
Connect the plug ST3 of the LIM-AC to the serial interface of the PC via
adapter TTL/RS232
(e.g.
FunkTronic RS232AD1). Start a perminal emulation prgramm (e.g. Hyperterminal, minicom). The
settings are 9600 baud, 8 data bits, no parity, one stopp bit and no flow control protocol.
Hit the ENTER key and you will receive the following display message:
LIM_AC (C) FunkTronic 02-03
Software: `LIM_AC` V1.1 vom 24.09.03
Pilotton: 3300 Hz
Rxx Read EEPROM Register xx
Pxx yy Program yy in EEPROM Register xx
X
Reset
If you enter R followed by a two digit register number and a final ENTER the setting of the correspon-
ding register will be displayed.
Programming a register works the same way but with the P button instead of R.
Enter P followed by the two digit register number followed by the register value and the final ENTER
key.
Input of X resets the unit.