1. DESCRIPTION

The Serial/Wifi converter 

TCP-485 WiFi

 allows the interconnection of the Full Gauge controllers 

with the supervisory software Sitrad through a WiFi data network using the TCP/IP communication 
protocol currently.
Many companies have Wireless routers in their facilities, and it is posible to use this same network for 
data  traffic  between  controllers  and  Sitrad  supervisory  software,  using  the 

TCP-485  WiFi

 

converter.

3. TECHNICAL ESPECIFICATIONS

Operating temperature

 

0 to 50ºC / 32 to 122ºF

Operating humidity

10 to 90% UR (without condensation) 

32 (without the need for termination)

4. INDICATIONS

5. INDICATIONS AND KEYS

Have this manual in your hands 

using the 

FG Finder

 application.

Converter power

External power supply 12 Vdc / 1A

Number of instruments supported 
per converter in the RS-485 network

Antenna

3,8dBi for a estable high quality connection

Product dimensions

43,5 x 16 x 34 mm (LxAxP)

Compatibility

 

IEEE 802.11 b/g up to 54 Mbps

Encryption type

WEP, WPA and WAP2

2. APLICATIONS

              

• Facilities where it is desirable to use the existing Wireless network;
• Facilities that do not have conditions for passing a new Ethernet data cabling;
• Facilities where the cost of the investment in the cabled structure has an impact;

Note:

  The 

TCP-485  WiFi

  converter  is  designed  to  work  only  with  Full  Gauge  Controls 

instruments.

Antenna  -  Connect  the  antenna 
supplied with the converter.

NOTE:

 Use only antenna supplied by 

Full Gauge.

Converter power

Reset - see item 7 - Reset configuration

Communication network with RS-485 instruments

Power  indication 
LED  -  Power  and 
signal  strength 
indication LED

Status  indication 
LED  -  connection 
status  indication 
LED

RS-485  network 
t r a n s m i s s i o n  
indication LED

RS-485  network 
r e c e p t i o n  
indication LED

Antenna dimensions

34,9 x 175,2 x 13 mm (LxAxD)

Supervisory

system

Wi-Fi

Serial

comunication

RS

485

Ocurrence

White / On

Contact Full Gauge Controls

Router connection password error

Equipament scanning the network

LED STATUS / State

LED POWER / State

TCP-485 WiFi

ALL MODES

CONFIGURATION

MODE

Contact Full Gauge Controls

Equipament ready to connect

Excellent signal level

No signal

Connected with Sitrad and communicating

Good signal level

Poor signal level

Very poor signal level

Equipament booting

White / On

Equipament connected and ready to be configured via internet browser

White / Flashing

Off

Red / On

Green / Flashing

Yellow / Flashing

Off

Red / Flashing

Red / Flashing

Red / On

Yellow / On

Red / On

Yellow / Flashing

Green / On

Blue / Flashing

Purple / Flashing

Blue / Flashing

Yellow / On

Blue / Flashing

Purple / On

Blue / Flashing

Red / On

Blue / On

Red / Flashing

Blue / Flashing

OPERATION

MODE

Power supply provided with the
converter

Input - 100-240Vac (50/60Hz) 
Output: 12Vdc / 2A

WARNING

ACCESSORIES:

Only use original accessories of Full Gauge Controls.
If you have any questions, please contact our technical support.

AUTHORIZED SERVICES:

The installation and maintenance of the product must only be performed by qualified personnel.

DUE TO CONSTANT EVOLUTION, FULL GAUGE CONTROLS RESERVES THE RIGHT TO CHANGE THE 
INFORMATION CONTAINED IN THIS MANUAL.

BEFORE INSTALLING THE CONTROLLER WE RECOMMEND READING THE INSTRUCTION 
MANUAL THOROUGHLY IN ORDER TO AVOID POSSIBLE DAMAGES TO THE PRODUCT.

PRECAUTIONS WHEN INSTALLING THE PRODUCT:

Before performing any procedure in this instrument, disconnect it from the mains; make sure the 
instrument has proper ventilation, avoiding installation in panels containing devices that may force 
it to work outside the specified temperature limits;
Install the product away from sources that can generate electromagnetic disturbances, such as: 
motors, contactors, relays, solenoid valves, etc.

Summary of Contents for TCP-485 WiFi

Page 1: ...nstruments Power indication LED Power and signal strength indicationLED Status indication LED connection status indication LED RS 485 network t r a n s m i s s i o n indicationLED RS 485 network r e c e p t i o n indicationLED Antenna dimensions 34 9 x 175 2 x 13 mm LxAxD Supervisory system Wi Fi Serial comunication RS 485 Ocurrence White On Contact Full Gauge Controls Router connection password e...

Page 2: ...formation may occur Check whether there is any barrier to the signal or any equipment that may interfere with the signal quality If the signal remains poor try installing the TCP 485 WiFi in another position or use a Wi Fi signal repeater With excellent or good signal connect the serial network to Terminals A and B of the converter and make the configurationsusingSitrad asperItem8ofthemanual NOTE ...

Page 3: ...e the option you want As an example we will use the Automatic Search option Step 4 Click on Select to register the new converter Check if everything is okay in the configurations andclickon Save Aftersaving theconverterwillappearinthelistonthelefthandside Step 3 The name of the TCP 485 WiFi must be displayed as configured in the web page of the converter Ifnot the Refresh buttonstartsanewsearchfor...

Page 4: ...figurebelow Note If this message is displayed on your Web browser temporarily disable the antivirus because someantivirusesblockthedisplayoftheavailablenetworks Step 5 To register the instruments that are in the RS 485 network of the new converter select the new converterfromthelisttotheleftandclickon SearchInstruments ontherighthandside Low Potential for interference Barrier types Synthetic mater...

Page 5: ... the laws in your area regarding disposal of electronic waste Ifindoubt pleasecontactFullGaugeControls WARRANTY FULL GAUGE CONTROLS Products manufactured by Full Gauge Controls as of May 2005 have a two 02 year warranty as of the date of the consigned sale as stated on the invoice They are guaranteed against manufacturing defects that make them unsuitable or inadequate for their intended use EXCEP...

Reviews: