background image

SET

1. DESCRIPTION

The 

Microsol

 

SWP Advanced

  is a differential thermostat for solar heating that 

controls the water circulation pump based on the temperature differential between the solar 
collector  and  the  pool  or  thermal  reservoir.  The  controller  has  functions  to  prevent 
overheating and freezing of water in the solar collector. Also provides access protection to 
the parameters configuration.
The 

Microsol

 

Advanced

   series is characterized by distinctive design for use in 

residential environments, by operation facility With easy access keys to main features of 
the controller and the use of the custom display. The display technology employed allows 
providing a simple and complete information of the solar heating system, such as: output 
status, operation mode of the pump, position and temperature of sensors.

2. APPLICATION

- Solar heating systems for swimming pools
- Solar heating systems for thermal reservoirs

3. TECHNICAL SPECIFICATIONS

-Power:

 

Microsol

 

SWP Advanced

230Vac 

±

10%(50/60Hz) or version 115Vac 

±

10%(50/60Hz)

- Operating temperature:

 0 to 50ºC

- Operating humidity:

 10 to 90% UR  (without condensation)

- Sensors:

 The 

Microsol

 

SWP Advanced 

 has 2 sensors:

              

Sensor T1: 

Solar Collector – SB59 Sensor, metal tip, Silicone, 1m

Sensor T2: 

Thermal reservoir – SB41 Sensor, plastic tip, 2m

- Control temperature: Sensor T1: 

-50 to 200ºC / -58 to 392ºF

Sensor T2: 

-50 to 105ºC / -58 to 221ºF

- Resolution: 

0.1ºC between -10 and 100ºC and 1ºC in the remaining range

1ºF in all range

- Control output: 

The 

Microsol

 

SWP Advanced 

has one relay output:

                             

PUMP

 - Relay output, max. 1HP in 220Vca (½ HP in 127 Vca)

- Dimensions: 

104 x 148 x 32 mm

- Display: 

LCD 2.75'' with backlight

4. INDICATIONS AND SCREEN

4.1 PRESENTATION

4.2 INDICATIONS

In programming, parameter setting released
In programming, parameter setting locked
Display of temperature on the Fahrenheit scale
Display of temperature on the Celsius scale
Pump on due the cooling function
Pump on due the antifreeze function
Pump on due the function of the vacuum tube
Pump on due the temperature differential (T1-T2)
Output of pump on
T1 sensor position - solar collector
T2 sensor position - pool / thermal reservoir
Indicates the occurrence of overheating T1
Indicates the occurrence of T1 sensor error - solar collector
Indicates the occurrence of T2 sensor error - pool / thermal reservoir
Indicates that the maximum differential (T1-T2) for protection against
thermal shock in the vacuum tube function has been exceeded
Lock functions enabled

5. OPERATIONS FOR DOMESTIC USER

5.1 MAP OF KEYS

The controller has facilitated accesses to the pertinent resources to the user. Following 
table describing these:

Short press: temperature setting for heating the pool / reservoir

Long press (4 seconds): access to advanced settings

Long press (see F17 parameter): enable/disable lock of functions

Short press: Toggles the display of the temperature (DIF, T1, T2) for 10 seconds

Short press: Toggles the pump mode for MANUAL ON (MAN)

Short press: Toggles the pump mode for AUTOMATIC (AUT)

Short press: Toggles the pump mode for OFF (Disconnected)

5.2 POOL/RESERVOIR HEATING TEMPERATURE (T2 SENSOR)

Sets the comfort temperature of the pool or thermal reservoir (T2). Upon 
reaching  this  temperature  the  water  circulation  pump  is  disconnected, 
avoiding thermal discomfort. To adjust this parameter give a short press on 
the 

SET 

key. Use     or    keys to adjust the value. To confirm this give a short 

press on the 

SET

 key and the value is saved in the controller's memory. This 

parameter can be adjusted between 0.0 to 105 °C or between 32 to 221°F.

5.3 PUMP WATER OPERATION MODE

To change the operation mode of the water pump use     ,     and     keys. The circulation 
water pump between the solar collector and thermal pool or reservoir can operate in three 
different modes. Description below:
                                             
                                                        

                                                

Obs.:

 In the pump mode adjustment, the controller assumes the new Mode 5 seconds 

after your selection. This is also the time required for the parameter to be stored in its 
memory.

When the MAN mode is selected (MANUAL), the operation mode remains in this state for the 
period defined in function 

[,F07]

 - Maximum pump time turned in manual mode. After, the 

controller takes on the AUT mode (AUTOMATIC). If you wish to return to AUT mode before this 
period, press the      key at any time.

5.4 VIEW OTHER TEMPERATURES

To toggle between the display of the T1 temperature sensor, T2 sensor or differential of 
these (T1-T2), give short press on       key until the desired temperature appears on the 
display. On digits in the upper display the measured temperature is displayed, and on the 
digits of the lower display the sensor description.
The selected temperature is displayed on the display for 10 seconds, after this preferential 
indication is displayed again, as set in 

[,F01]

 parameter -

 

Preferred Indication.

5.5 LOCK OF FUNCTIONS

For security purposes and to prevent unauthorized users from changing the settings of the 
controller, there is a lockout of functions feature. With this setting enabled, the parameters 
cannot be changed, however, can be viewed. In the lock condition, trying to change the 
value of a parameter is displayed the

 [,LOC][,,On]

 message on the display.

To enable / disable the locking function should keep pressed the     key the time set in 
parameter 

[,F17]

 - Time to lock functions.

The icon       indicates the user the lock state, when lit indicates that the lock function is 
active.

CLUE:

 with the lock functions enabled, you avoid children, visitors or curious will change 

the operation mode or controller parameters. When there is need for a change, just hold 
down the      key to enable / disable this feature.

1
2
3
4
5
6
7
8
9

10
11

MAN Pump Mode Key (Manual)
AUT Pump Mode Key (Automatic)
OFF Pump Mode Key (Disconnected)
Decrease Key 
SET Key
Increase Key
Pump operation mode indication
Signs of the controller
Solar heating system indication
Digits of the lower display
Digits of the upper display

SET

LOC

MAX

+

+

+

AUT

PUMP

off

PUMP

MAN

PUMP

SET

SET

6. ADVANCED OPERATIONS FOR INSTALLER (TECHNICAL USE)

6.1 CHANGE OF CONTROLLER PARAMETERS

Access the settings menu by pressing the 

SET

 key for 4 seconds until 

[FuNc]

 appears. 

Then

 [Code]

 appears, then press the 

SET

 key again, short press. Use the    or    keys 

to enter the value of the access code 123, and when ready press the 

SET

 key (short 

press) again.
Use the    or    keys to select the desired function. With a short press on the 

SET

 key you 

can edit its value. Use the     or     keys to change the value, when ready give a short press 
the 

SET 

key to store the set value and return to the function menu.

To exit the menu and return to normal operation (temperature indication) press and hold 
the 

SET

 key (long press) until 

[----]

appears.

MCSOLADV

ANSWP02-01T

-17098

DIFFERENTIAL THERMOSTAT 

FOR SOLAR HEATING

Ver. 02

A

SET

1

2

3

6

5

4

MAX

am pm

SET LOC

AUT

off

MAN

PUMP

7

8

11

9

10

am

pm

AUT

PUMP

SWP

AUT= Circulation pump in automatic mode 
operating as setting of the parameters

         MAN= Circulation pump On 

        OFF= Circulation pump always turned off 

Attention: 

In this mode the pump is maintained turned on , 

ignoring the protection functions and temperature sensors

.

MAX

+

+