4. INDICATIONS AND KEYS
5.1 INSTALLATION - ELECTRICAL CONNECTIONS
6. OPERATIONS
6.1 Quick Access Menu Map
To access or navigate the quick access menu using the
;
(short press) key while the controller is
displaying the temperature. For every touch, the next function in the list is displayed. To confirm, use the
/
(short press) key.
6.2 Quick access keys map
When the controller is on temperature display, the following keys serve as a shortcut for the following
functions:
1. DESCRIPTION
2. APPLICATION
3. TECHNICAL SPECIFICATIONS
For frozen products, it automates the defrost processes according to the need of installation (smart
defrost). Its output relay directly controls compressors of up to 2HP and its defrost output has a current
capacity of 10A. The ambient temperature control has a normal setpoint and an economic setpoint,
apart from the fast freezing function and alarm functions indicating open door. It also features a digital
filter, intended to simulate a mass increase in the ambient sensor (S1), thus increasing its response time
(thermal inertia) and avoiding unnecessary drives of the compressor. It also includes a smart key, lock
system and a control functions shutdown mode.
Product complies with UL Inc. (United States and Canada) and NSF (
.
• Cold Storage Rooms
• Display freezers
United States)
evolution
Connection 115 Vac
/
<
<
<
<
Pressed for 2 seconds: setpoint adjustment.
Short press: displays process.
Short press: display of minimum and maximum measurement records.
Enters the functions selection.
6.3 Basic operations
6.3.1Setting the desired temperature
To access the setpoints setup menu press
/
for 2 seconds. The message
[SP,,]
will appear on the
display followed by the normal setpoint set value. Use the
>
or
<
to modify the value and confirm by
pressing
/
. Immediately, the message
[SP-e]
appears indicating the setting of the economic
setpoint. Again, use the
>
or
<
keys to modify the value and confirm by pressing
/
. Finally, the
[----]
indication signals the setup completion. The setpoints can also be adjusted individually in the
quick access menu.
<
Pressed for 2 seconds: inhibits audible alarm.
<
Pressed for 2 seconds: when displaying records, it cleans the history.
1
5 6 7 8
2 3 4
9
10 11 12 13 14 15 16 17
Sensor S1
D1/S3
D2
Sensor S2
230 Vac
CO
MP
DE
FR
FA
NS /
Panel (Front View)
Panel
(Side View)
Dimension of the clipping
for fixing of the
instrument in panel
71
mm
± 0,5
29
mm
± 0,5
DE
FR 2
;
Enters the quick access menu.
1
5 6 7 8
2 3 4
9
10 11 12 13 14 15 16 17
Sensor S1
D1/S3
D2
Sensor S2
CO
MP
DE
FR
Connection 230 Vac
115 Vac
FA
NS /
DE
FR 2
5. INSTALLATION - ASSEMBLING
and
Control functions
shutdown
Functions
lockdown
Serial
programming
Protection
level
IP 65
FRONT
Fast Freezing
FAST FREEZING (ON/OFF)
;
TC-900
e
2HP
;
ECONOMIC SETPOINT(ON/OFF)
TC-900
e
2HP
;
DEFROST (ON/OFF)
TC-900
e
2HP
;
FUNCTIONS LOCKDOWN
TC-900
e
2HP
;
CONTROL FUNCTIONS
(ON/OFF)
TC-900
e
2HP
NORMAL SETPOINT
;
TC-900
e
2HP
ECONOMIC SETPOINT
;
TC-900
e
2HP
MIN. AND MAX. TEMPERATURE
RECORD
;
TC-900
e
2HP
ERASE MIN. AND MAX.
VALUES
;
TC-900
e
2HP
EXIT FUNCTION
;
TC-900
e
2HP
FUNCTION SELECTION
;
TC-900
e
2HP
The
sensor S1 (black)
must be in the ambient.
The
sensor S2 (gray)
must
be placed in the evaporator
through metallic cramp.
DIGITAL CONTROLLER FOR
REFRIGERATION AND DEFROST
<
ATTENTION
FOR INSTALLATIONS WHERE A SEALING IS REQUIRED TO
AVOID LIQUID CONTACT, THE CUT FOR THE CONTROLLER
MUST BE OF 70,5X29mm MAXIMUM. THE SIDE LOCKS MUST
BE FIXED SO IT PRESSES THE RUBBER SEALING AVOIDING
INFILTRATION BETWEEN THE CUT AND THE CONTROLLER.
IMPORTANT
SCREWDRIVER SLOT 3/32''(2.4mm) FOR ADJUSTMENTS IN THE
SIGNAL TERMINALS;
SCREWDRIVER PHILLIPS #1 FOR ADJUSTMENTS IN THE POWER
TERMINALS;
THE USE OF APPROPRIATE TOOLS IS ESSENTIAL TO AVOID DAMAGE
IN THE CONNECTION AT INSTRUMENT TERMINALS:
Pressed for 4 seconds: performs manual defrost.
TC-900
e
2HP
Set key
Quick Access
Menu Key
Increase key
Decrease key
Compressor output
indication LED
Fan indication LED
Defrost indication LED
Functions lock indication LED
Control functions shutdown
indication LED
Temperature unit indication LED
Control temperature
-50°C to 105°C / -58°F to 221°F
Power supply
TC-900E 2HP:
115 or 230Vac ±10% (50/60Hz)
Operating temperature
0 to 50°C / 32 to 122°F
Operating humidity
10 to 85 %RH (without condensation)
Dimensions (mm)
76 x 34 x 77 mm (WxHxD)
Load current (outputs)
COMP:
16(12) 2HP 240Vac
DEFR:
10A / 240Vac 2400W
FANS:
5(3)A / 240Vac
Dimensions of the clipping for fixing
of the instrument
71 ± 0,5 x 29 ± 0,5 mm (see item 5)
Pressed for 5 seconds: turn on/turn off the control functions.
;
TC900E2HP07-01T
-15839
TC-900
e
2HP
TC-900
e
2HP
Ver
.07
TC-900
e
2HP
E251415
COMPONENT
Have this manual in the palm of
your hand by
FG Finder
application.