11
KNOW YOUR PRODUCT
SET UP & PREPARATION
Under normal use conditions, the tool should be lubricated with air tool oil before
connecting the tool to an air supply. Add air tool lubricate into the air tool once
daily with minimal use, or twice a day with heavy use. Only a few drops of oil
at a time is necessary. Too much oil will only collect inside the tool and will be
noticeable in the exhaust cycle. Warning! use only air tool oil to lubricate the tool.
Before connecting the tool, check the air compressor gauge to be sure it is
functioning within the proper range 6.2 bar (90 psi).
Note:
The tool and air hose must have a quick-connect hose coupling that allows
all pressure to be removed from the tool when the coupling is disconnected.
1.
Pull back the sleeve on female quick connector hose coupling, insert male end
and release sleeve on quick connector.
Note:
For best performance use 3/8” I/D supply air hose.
WARNING!
Ensure the tool is in the off position before connecting to the
air supply.
WARNING!
Always use a coupling that discharges all the compressed
air in the tool at the time the fitting or hose coupling is disconnected.
Using a coupling that does not discharge the compressed air could cause
unintended operation and serious personal injury..
Connecting air supply
1. Wrap Teflon tape (not supplied) around the Nitto Style Fitting approximately 4
to 5 times to ensure a leak free seal.
2. Screw in Nitto Style Fitting to the air inlet of the Air Wrench.
3. Fasten the Nitto Style Fitting using a 14mm spanner (not supplied).