When using electrical equipment, including this emergency exit product, basic safety
precautions should be followed at all times, including but not limited to the following:
PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR SAFETY
6. Any modification or use of non-original components will void the warranty and product liability.
8. Servicing of this equipment should be performed by qualified service personnel only.
1.
All electrical connections must be in accordance with local codes, ordinances and the National
3. Do not mount near gas or electric heater.
9. Unpack and check for concealed transit damage.
4. Equipment should be mounted in location and at heights where it will not be readily subjected to
tampering by unauthorized personnel.
5. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
7. Do not use this equipment for anything other than the intended use.
SAVE THESE INSTRUCTIONS
Page 1 of 2
20
-
Rev A
18 784
Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060.
Specifications subject to change without notice.
[email protected] www.fulham.com
Electric code.
2. Do not use outdoors.
THIS UNIT IS FOR MOUNTING IN SUSPENDED TYPE CEILINGS AND OTHER TYPES OF CEILINGS WHERE
ACCESS TO ABOVE IS AVAILABLE AFTER INSTALLATION AND BUILDING FINISH IS COMPLETE. DO NOT
INSTALL THIS UNIT IN FINISHED DRYWALL OR OTHER TYPES OF CEILINGS WHERE THERE WILL BE NO
ACCESS FROM ABOVE OR BELOW TO THE PLENUM AREA.
PLEASE NOTE:
ACCESS ABOVE CEILING IS REQUIRED
1) Determine the proper location for where the sign is going to be mounted. Remove cardboard template from the box
2) Cut the rectangular hole out of the ceiling area (Figure B)
3) Place entire unit DOWN THROUGH THE CUT OUT HOLE. (Figure C)
4) Seat the bar hangers in the T-Bar grid or mount them to the wood truss to secure the fixture in place. (Figure D)
5) Make adjustments to the bar hanger holder bracket (Figure E) to bring the fixture into proper ceiling height alignment
6) Slide the silver finish plate through the EXIT PANEL and connect the two switch wires and place the LED indicator
1. Remove the junction box cover on the top of the unit. (Figure H)
STEP ONE:
Preparing the CEILING to ACCEPT the fixture and placing fixture in the ceiling:
GENERAL INSTALLATION
GUIDELINES FOR
RECESSED EDGE-LIT
(FHEX23)
and place against the ceiling tile orarea of the ceiling where exit light is going to be installed and trace a line around
the template (Figure A). This will be the area that is going to be cut out. You may want to do the cutting on the
ground if possible
to accept the finish trim plate. This height is determined by making sure the finish plate screw holes are just slightily
above the finished ceiling (Figure E). To make the adjustments, simply loosen the screws on the bar hanger holder
bracket and adjust unit up or down to the proper position and then re-tighten the screws (Figure F)
light inside the hole. (Figure G) Screw the plate to the unit.
2. Place conduit connector in provided hole of J-box. (Figure J)
3. Connect the low voltage battery wires. The unit will turn on at this point. (Figure K)
4. Make the proper electrical AC connection by bringing the supply wires into the J-box and connecting them
to the proper wires. (120V BLACK for HOT, WHITE for Common) (277V use RED for HOT and WHITE for Common)
5. Replace J-box cover.