15-5
Chapter 15 Setup Item/Default Value
Review Function
Review Function
Graphic Trend
Item
Description
Default
Setting at
Discharge
Trend A
(H Module)
HR, ST1, ST2, ST (I to V6) , SpO
2
, SpO
2
-2, PR_ SpO
2
,
PR_ SpO
2
-2,VPC, NIBP, BP1 to 8, PR_IBP, PDP,
CPP, T1 to 8, Tb, RR_IMP, APNEA, EtCO
2
, InspCO
2
,
RR_ GAS, ExpN
2
O, InspN
2
O, ExpAGT, InspAGT,
MAC, RR_VENT, ExpO
2
, InspO
2
, PI, PI-2, PVI, PVI-2,
SpCO, SpCO-2, SpMet, SpMet-2, SpHb, SpHb-2,
PEAK, PEEP, ExpMV
(Vigilance)
SvO
2
, ScvO
2
, CCO, CCI, BT
(Other)
BIS, Lt-rSO
2
, Rt-rSO
2
, S1-rSO
2
, S2-rSO
2
Upper Row: HR, OFF, OFF, NIBP
Middle Row: SpO
2,
OFF, T1, RR_IMP
Lower Row: OFF, OFF, OFF, OFF
No Change
Trend B
Upper Row: HR, BP1, T1, NIBP
Middle Row: SpO
2
, EtCO
2
, ST (II) ,
RR_GAS
Lower Row: OFF, OFF, OFF, OFF
No Change
Trend C
Upper Row: HR, T1, BP1, NIBP
Middle Row: SpO
2,
InspCO
2
, EtCO
2
,
InspAGT
Lower Row: OFF
No Change
Trend D
Upper Row: OFF, OFF, OFF, OFF
Middle Row: OFF, OFF, OFF, OFF
Lower Row: OFF, OFF, OFF, OFF
No Change
Time Span
20min. 1h, 2h, 4h, 8h, 12h, 16h, 24h
4 hours
No Change
Graphic Display
A:
,
,
,
,
,
,
,
,
B:
,
,
,
,
,
,
,
C:
,
D:
,
E:
,
,
,
Scale,
Display Selection
HR, PR_SpO
2
, PR_IBP
100, 200, 300bpm
(Graphic A)
300bpm
No Change
ST1, ST2,
ST (I to V6)
± 0.2, ± 0.5,± 1.0, ± 2.0mV ± 0.5mV
No Change
± 2.0, ± 5.0, ± 10.0, ±
20.0mm
(Graphic B)
± 5.0mm
VPC
20, 50, 100 beats
(Graphic C)
20 beats
No Change
BP1 to BP8 (S/D/M)
20, 50, 100, 150, 200,
300mmHg
4, 8, 16, 20, 24, 40kPa
(Graphic D)
200mmHg
24kPa
No Change
PDP, CPP
20, 50, 100, 150, 200,
300mmHg
4, 8, 16, 20, 24, 40kPa
(Graphic A)
200mmHg
24kPa
No Change
NIBP (S/D/M)
100, 150, 200, 300mmHg
16, 20, 24, 40.0kPa
(Graphic E)
200mmHg
24kPa
No Change
T1 to T8
20.0-45.0, 30.0-40.0°C
(Graphic A)
30.0-40.0°C
No Change
SpO
2
, SpO
2
-2
0-100, 50-100, 80-100%
(Graphic A)
80-100%
No Change
SpCO, SpCO-2
20, 40, 100% (Graphic A)
20%
No Change
SpMet, SpMet-2
10, 15, 100% (Graphic A)
10%
No Change
SpHb, SpHb-2
10.0-20.0, 0-25.0g/dL
(Graphic A)
10.0-20.0g/dL
No Change
Summary of Contents for DYASCOPE 8000 Series
Page 1: ......
Page 2: ......
Page 12: ...Contents ...
Page 20: ...Contents ...
Page 44: ...1 2 Chapter 1 General Description Contents ...
Page 50: ...2 2 Chapter 2 Name of Parts and Their Functions Contents ...
Page 54: ...2 4 Chapter 2 Name of Parts and Their Functions ...
Page 56: ...3 2 Chapter 3 Description of the Display Contents ...
Page 70: ...4 2 Chapter 4 Basic Operation Contents ...
Page 82: ...5 2 Chapter 5 Preparation Contents ...
Page 88: ...5 6 Chapter 5 Preparation Nurse Call Daily Check ...
Page 90: ...6 2 Chapter 6 Admit Discharge Contents ...
Page 110: ...7 2 Chapter 7 Alarm Function Contents ...
Page 138: ...8 2 Chapter 8 Parameter Setup Contents ...
Page 164: ...8 26 Chapter 8 Parameter Setup Parameter ON OFF ...
Page 166: ...9 2 Chapter 9 Data Review Contents ...
Page 190: ...10 2 Chapter 10 Waveform Review Contents ...
Page 206: ...11 2 Chapter 11 Calculation Contents ...
Page 212: ...12 2 Chapter 12 Printing Contents ...
Page 230: ...13 2 Chapter 13 Menu Items Contents ...
Page 270: ...13 40 Chapter 13 Menu Items Nurse Team Setup ...
Page 272: ...14 2 Chapter 14 Troubleshooting Contents ...
Page 296: ...14 24 Chapter 14 Troubleshooting Troubleshooting ...
Page 298: ...15 2 Chapter 15 Setup Item Default Value Contents ...
Page 320: ...15 22 Chapter 15 Setup Item Default Value Menu Central Monitor Display ...
Page 322: ...16 2 Chapter 16 Accessories Contents ...
Page 326: ...16 4 Chapter 16 Accessories Optional Accessories ...
Page 328: ...17 2 Chapter 17 Specification Contents ...
Page 342: ...17 14 Chapter 17 Specification Technical Information ...
Page 347: ......
Page 348: ......
Page 349: ......