Precautions for Using the Equipment
The alarm generated on the bedside monitor will be transmitted to the central monitor with maximum of 5
seconds delay for the NIBP alarm and maximum of 2 seconds delay for other alarms.
If the measurement unit for BP (mmHg/kPa) and temperature (
°
C/
°
F) is different between the bedside monitor
and the central monitor, the corresponding waveform and numeric data will not be displayed on the central
monitor.
If the numeric data is displayed as "xxx" (out of measurement range) on the bedside monitor, maximum or
minimum value of measurable range will be transmitted to the central monitor.
Wireless Network System
When monitoring a patient using medical telemetry, make sure the patient data is properly received at the
central monitor. Pay special attention when the channel ID at the bedside monitor is changed.
Make sure to set the correct channel ID.
Some combinations of channels may generate interference with other telemetry transmitters. Before selecting
a channel, verify it will not interfere with other channels.
Make sure the telemetry manager of your system is aware of any changes to the telemetry channels.
If transmitters are used in a neighboring medical facility, your facility and neighboring facility must make
agreements on the setting of telemetry channels to prevent telemetry interference.
If the channel ID of the transmitter is changed, make sure to replace the channel label attached to the transmitter
with a new one.
If the channel ID is changed without notifying, it will result in monitoring an incorrect patient. To avoid
incorrect diagnosis, make sure that the channel ID corresponds to the patient.
When using the wireless system and TCON at the same time, the registered channel ID will be automatically
assigned for the TCON bed. Therefore, if the same channel ID is registered for another bed, malfunction may
occur. Make sure to set a unique channel ID for each bed.
When using the wireless system and TCON at the same time, the numeric data from the telemeter will be
displayed. Even when the telemetry condition is poor, numeric data from TCON will not be displayed.
On a wireless network system, the alarm generated on the bedside monitor will be transmitted to the central
monitor with maximum of 13 seconds delay for the NIBP alarm and maximum of 7 seconds delay for other
alarms.
TCON System
The date/time setting of the TCON remote station synchronizes with the TCON base station. However, if the
TCON remote station is connected to the wired network, the date/time setting synchronizes with the network
administrating monitor (central ID: 001).
The TCON installation and setup should be performed by our service representative. The users should not
attempt them.
Follow the instructions of the Overall Manager for the wireless channel when setting the TCON ID or channel
(group) to prevent interference within the same institution.
The same TCON channel (group) should be set for the central monitors and bedside monitors within the same
TCON group.
DANGER
WARNING
CAUTION
CAUTION
Summary of Contents for DYASCOPE 8000 Series
Page 1: ......
Page 2: ......
Page 12: ...Contents ...
Page 20: ...Contents ...
Page 44: ...1 2 Chapter 1 General Description Contents ...
Page 50: ...2 2 Chapter 2 Name of Parts and Their Functions Contents ...
Page 54: ...2 4 Chapter 2 Name of Parts and Their Functions ...
Page 56: ...3 2 Chapter 3 Description of the Display Contents ...
Page 70: ...4 2 Chapter 4 Basic Operation Contents ...
Page 82: ...5 2 Chapter 5 Preparation Contents ...
Page 88: ...5 6 Chapter 5 Preparation Nurse Call Daily Check ...
Page 90: ...6 2 Chapter 6 Admit Discharge Contents ...
Page 110: ...7 2 Chapter 7 Alarm Function Contents ...
Page 138: ...8 2 Chapter 8 Parameter Setup Contents ...
Page 164: ...8 26 Chapter 8 Parameter Setup Parameter ON OFF ...
Page 166: ...9 2 Chapter 9 Data Review Contents ...
Page 190: ...10 2 Chapter 10 Waveform Review Contents ...
Page 206: ...11 2 Chapter 11 Calculation Contents ...
Page 212: ...12 2 Chapter 12 Printing Contents ...
Page 230: ...13 2 Chapter 13 Menu Items Contents ...
Page 270: ...13 40 Chapter 13 Menu Items Nurse Team Setup ...
Page 272: ...14 2 Chapter 14 Troubleshooting Contents ...
Page 296: ...14 24 Chapter 14 Troubleshooting Troubleshooting ...
Page 298: ...15 2 Chapter 15 Setup Item Default Value Contents ...
Page 320: ...15 22 Chapter 15 Setup Item Default Value Menu Central Monitor Display ...
Page 322: ...16 2 Chapter 16 Accessories Contents ...
Page 326: ...16 4 Chapter 16 Accessories Optional Accessories ...
Page 328: ...17 2 Chapter 17 Specification Contents ...
Page 342: ...17 14 Chapter 17 Specification Technical Information ...
Page 347: ......
Page 348: ......
Page 349: ......