Safety
Precautions for Using the Equipment
perform this procedure as malfunction may occur.
Do not attach film or adhesive tape to the touch panel. It may cause malfunction or damage the touch panel.
As the touch panel is made of glass, a strong impact may cause damage. Pay attention not to hit or drop the
touch panel.
Always operate the touch panel with fingers or a touch panel pen. Do not touch with a pen-point or other hard-
edged instruments. It may cause malfunction. In addition, do not apply pressure to whole or part of the panel
for a prolonged time.
Do not press the touch panel with strength or twist your finger on the panel. It may cause malfunction or
damage the touch panel.
Due to its material characteristic, the touch panel expands/contracts depending on the temperature/humidity.
The LCD of this equipment utilizes LED for the backlight. Since this LED deteriorates by the life cycle, the
display may become dark, scintillate, or may not light by the long term use. In such case, contact your nearest
service representative.
Precautions about the System
The time will be synchronized with the following priority.
1 Administrating monitor, if wired network is constructed.
2 TCON base station, if TCON system is used.
3 SNTP server, if used.
4 Patient data server, if used, and if [Time Synchronization] is selected on Patient Data Server setup or
"Time Synchronization" is set to [ON] for [Link with EMR] or [Search ID].
Verify that the correct date/time is set on the "Initial Settings>System>Other" before monitoring. If the date/
time is changed during monitoring, error may be caused to the trend data or other patient data.
Many of the "Initial Settings" items can be set only on the network-administrating monitor (Central ID: 001).
These settings will not be displayed on other central monitors.
Canceling the bed registration will clear all data for that bed.
The "Drift Filter" setting on the "Initial Settings>Meas.>Other" should be the same for all central monitors.
Proper operation will not be performed if the setting is different among the central monitors.
Unless the correct power frequency is set for "AC Filter" ("Initial Settings" > "System"), the AC filter will not
properly function.
Do not use any slave monitors which does not satisfy the required display resolution. Do not use any monitors
which has the function to display higher resolution than the actual resolution.
Precautions about the CF Card, Data Transfer
Do not use unspecified CF card.
Use only the CF card formatted on this equipment.
When removing the CF card, make sure that the CF card indicator is not lit.
Check that the CF card indicator is not lit in red when turning OFF the power.
The data transfer using the CF card is possible only between the DS-8900 System central monitors. The data
cannot be transferred to other central monitors or to bedside monitors.
If the software version of the two DS-8900 System central monitors are different, the data transfer may not be
possible, or part of the data may not be transferred. (The data transfer from the newer version monitor to the
older version monitor is not possible.)
Precautions about the Patient Admit/Discharge
Make sure to discharge the previous patient before admitting a new patient. Otherwise, monitoring data of new
patient will be added to that of the previous patient which will result in inaccurate monitoring.
When a patient is discharged, make sure to perform the discharge procedure.
CAUTION
CAUTION
CAUTION
Summary of Contents for DYASCOPE 8000 Series
Page 1: ......
Page 2: ......
Page 12: ...Contents ...
Page 20: ...Contents ...
Page 44: ...1 2 Chapter 1 General Description Contents ...
Page 50: ...2 2 Chapter 2 Name of Parts and Their Functions Contents ...
Page 54: ...2 4 Chapter 2 Name of Parts and Their Functions ...
Page 56: ...3 2 Chapter 3 Description of the Display Contents ...
Page 70: ...4 2 Chapter 4 Basic Operation Contents ...
Page 82: ...5 2 Chapter 5 Preparation Contents ...
Page 88: ...5 6 Chapter 5 Preparation Nurse Call Daily Check ...
Page 90: ...6 2 Chapter 6 Admit Discharge Contents ...
Page 110: ...7 2 Chapter 7 Alarm Function Contents ...
Page 138: ...8 2 Chapter 8 Parameter Setup Contents ...
Page 164: ...8 26 Chapter 8 Parameter Setup Parameter ON OFF ...
Page 166: ...9 2 Chapter 9 Data Review Contents ...
Page 190: ...10 2 Chapter 10 Waveform Review Contents ...
Page 206: ...11 2 Chapter 11 Calculation Contents ...
Page 212: ...12 2 Chapter 12 Printing Contents ...
Page 230: ...13 2 Chapter 13 Menu Items Contents ...
Page 270: ...13 40 Chapter 13 Menu Items Nurse Team Setup ...
Page 272: ...14 2 Chapter 14 Troubleshooting Contents ...
Page 296: ...14 24 Chapter 14 Troubleshooting Troubleshooting ...
Page 298: ...15 2 Chapter 15 Setup Item Default Value Contents ...
Page 320: ...15 22 Chapter 15 Setup Item Default Value Menu Central Monitor Display ...
Page 322: ...16 2 Chapter 16 Accessories Contents ...
Page 326: ...16 4 Chapter 16 Accessories Optional Accessories ...
Page 328: ...17 2 Chapter 17 Specification Contents ...
Page 342: ...17 14 Chapter 17 Specification Technical Information ...
Page 347: ......
Page 348: ......
Page 349: ......