SPARC Enterprise T5440 Server Service Manual • July 2009
FIGURE:
Removing a CMP Module
3. Slide the module up and out of the system.
4. Place the module on an antistatic mat.
▼
Install a CMP/Memory Module
Note –
If you are replacing a faulty CMP or memory module, you must transfer the
FB-DIMMs on the faulty module to the replacement module. Replacement
CMP/memory modules do not include FB-DIMMs.
For more information about installing FB-DIMMs, see
1. Identify the correct slot for installation.