Fixed in Other Software
6624658
If the host has been stopped from the domain side
and not from the SP, the
HOST_LAST_POWER_STATE
policy has been
enabled, and the AC power to the SP is cycled, then
the host starts automatically when the SP boots.
Note - Fixed in System Firmware 7.1.3.d or later.
You can stop the host through any of the available user
interfaces. For example, from the ILOM CLI use the
stop /SYS
command.
6613209
When moving the SCC chip from one system to
another, if the value of
/HOST/diag trigger
(or
diag_trigger
) has two values (such as
power-
on-reset
error-reset
), the values are restored
incorrectly from the SCC chip to the new system.
The values will be restored without a space
separating them (for example,
power-on-reseterror-reset
). This situation
will result in POST not being run when the host is
reset.
Note - Fixed in System Firmware 7.1.3.d or later.
When moving an SCC chip from one system to
another, verify that the values of
/HOST/diag trigger
are correct. If the values are
not correct, set them to the desired value.
6612947
Usually, after a power failure the server resets and
reboots automatically. When the power failure is very
brief, the host might hang while the SP continues to
operate as though the host was still functioning. The
entire system can appear to be hung.
Note - Fixed in System Firmware 7.1.3.d or later.
Log into the service processor and reset the system.
6610641
When unconfiguring a hard drive using
cfgadm
(1M), the blue Okay To Remove LED on the
hard disk will turn on, indicating that it is safe to
remove the hard drive. However, if the Solaris OS is
rebooted without having removed the unconfigured
hard drive, the drive gets reconfigured, but the Okay
To Remove LED stays on, indicating incorrectly that
the hard disk is in a safe-to-remove condition.
Note - Fixed in System Firmware 7.1.3.d or later.
Avoid rebooting the Solaris OS between hard drive
configure and unconfigure operations.
TABLE A-13
Issues Fixed in Other Software
CR ID
Description
Workaround
6651903
SunVTS
xnetlbtest
fails intermittently when run
in internal loopback mode for longer test durations.
Failures occur with this error message:
Excessive packets dropped
Note - Fixed in SunVTS6.4ps4 or later.
TABLE A-12
Issues Fixed in System Firmware 7.1.3.d or Later
(Continued)
CR ID
Description
Workaround
Summary of Contents for SPARC Enterprise T5140
Page 4: ......
Page 34: ...24 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 56: ...46 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 72: ...62 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 138: ...128 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...