Appendix A
Fixed Issues
113
Fixed in System Firmware 7.1.6.d or Later
TABLE A-11
Issues Fixed in System Firmware 7.1.6.d or Later
CR ID
Description
Workaround
6735254
After host activation, the CPU strand component may
become disabled.
Example of display from host side:
T5140, No Keyboard
Copyright 2008 Sun Microsystems,
Inc. All rights reserved.
OpenBoot 4.28.8, 32544 MB memory
available, Serial #XXXXXXXX.
Ethernet address XX:XX:XX:XX:XX:XX,
Host ID: XXXXXXXX.
ERROR: The following devices are
disabled: MB/CMP1/P0
*The numerical
figures may change depending on the system
configuration.
Note - Fixed in System Firmware 7.1.6.d or later.
None.
Recovery procedure: Execute recovery by using the
following procedure.
If the phenomenon occurs even after executing the
recovery procedure, the CPU component may be
faulty. Replace the CPU component.
[For ILOM]
1. Delete the CPU strand component from the asr-db
blacklist.
Example:
• set /SYS/MB/CMP1/P0 component_state=
enabled
[For ALOM]
1. Delete the CPU strand component from the asr-db
blacklist.
• e
nablecomponent /SYS/MB/CMP1/P0
6728569
When you logged in to ILOM from SSH client, it
takes 20 to 30 seconds or more before the login
completes (before the ILOM prompt "
->
" or "
SC>
"
displayed). It normally takes about 10 seconds.
Note - Fixed in System Firmware 7.1.6.d or later.
Power off the system, disconnect the power cord, wait
for about 180 seconds, and then reconnect the power
cord.
6703910
The built-in fan high-speed periodical diagnosis
activates every few hours, and the built-in fan
operates at high speed. At this time, fan speed of the
built-in fan goes up to the maximum, which increases
the fan noise of the built-in fan.
Note - Fixed in System Firmware 7.1.6.d or later.
None.
The fan high-speed test has no impact on system.
6694475
It is impossible to use options of the
showfru
command on the ALOM CMT compatibility shell.
All information will be displayed regardless of the
option specified.
showfru [-g lines] [-s|-d] [FRU]
-g
: Only the specified line
-s
: Only static information
-d
: Only dynamic information
Note - Fixed in System Firmware 7.1.6.d or later.
None.
Summary of Contents for SPARC Enterprise T5140
Page 4: ......
Page 34: ...24 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 56: ...46 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 72: ...62 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 138: ...128 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...