Appendix A
Fixed Issues
93
The ILOM event log example:
When this event occurred, power off the system and then reset the ILOM. After the reset
complete, wait for about 180 seconds and then power on the system.
Workaround:
After you insert the power cord, or after the ILOM reset complete, wait for
about 180 seconds and then power on the system.
Fixed in System Firmware 7.2.7.b or Later
15
Tue Apr 6 09:41:17 2010 Fault Fault critical
SP detected fault at time Tue Apr 6 09:41:17 2010. /SYS/MB/RISER0/PCIE3/
F20CARD prom is unreadable or corrupted
TABLE A-8
Issues Fixed in System Firmware 7.2.7.b or Later
CR ID
Description
Workaround
6857271
During SCC module replacement, part of the data
kept on the motherboard is inadvertently overwritten
with new SCC module data. This results in a
connection failure to the ILOM network.
For details, see
“After the SCC Module Replacement,
a Connection to the ILOM Network May Fail (CR
6857271)” on page 96
Note - Fixed in System Firmware 7.2.7.b or later.
If only the SCC module fails, replace the SCC module
together with the motherboard.
After replacing these components, restore the backed
up contents.
6856163
If the service processor is initialized with the LAN
cable disconnected from the ILOM network port, the
ILOM firmware serial console window displays an
error message indicating a failure to start an ILOM
internal process. As a result, ILOM fails to start.
For details, see
“When the Service Processor Is
Initialized, ILOM May Fails to Start with an Error
Message Displayed (CR 6856163)” on page 97
.
Note - Fixed in System Firmware 7.2.7.b or later.
1. Disconnect the power cord.
2. Connect the LAN cable to the ILOM network port.
3. Connect the power cord.
4. Verify that the ILOM network port is linked up.
6854379
After the replacement of motherboard, the values for
properties stored in the
/HOST/diag
directory may
not be carried over, even though system configuration
card (SCC module) is moved to the new
motherboard.
Note - Fixed in System Firmware 7.2.7.b or later.
None.
Before replacing the motherboard, back up the ILOM
settings. After the replacement, restore the backed up
settings.
Summary of Contents for SPARC Enterprise T5140
Page 4: ......
Page 34: ...24 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 56: ...46 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 72: ...62 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 138: ...128 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...