Appendix A
Fixed Issues
111
During the Power-On Self-Test, the Diagnostic
Process May Terminate Halfway (CR 6835860)
This issue is resolved by updating the system firmware to 7.2.7.b or later.
For SPARC Enterprise T5220 Server, during the power-on self-test (POST), the
"
ERROR:POST timed out
" message may appear and the diagnostic process may
terminate halfway.
Example:
Workaround: None. Power on the host again and perform the power-on self-test
(POST).
sc>
poweron -c
Enter #. to return to ALOM.
Chassis | major: Host has been powered on
0:0:0>
0:0:0>SPARC-Enterprise[TM] T5120/T5220 POST
4.30.2.build_06***PROTOTYPE BUILD***
2009/03/19 08:25
/export/delivery/delivery/4.30/4.30.2.build_06/post4.30.x/Niagara
/huron/integrated (root)
0:0:0>Copyright 2009 Sun Microsystems, Inc. All rights reserved
0:0:0>POST enabling CMP 0 threads: ffffffff.ffffffff
0:0:0>VBSC mode is: 00000000.00000001
0:0:0>VBSC level is: 00000000.00000001
0:0:0>VBSC selecting Normal mode, MAX Testing.
0:0:0>VBSC setting verbosity level 2
0:0:0>Basic Memory Tests....Done
0:0:0>Test Memory....Done
0:0:0>Setup POST Mailbox ....Done
0:0:0>Master CPU Tests Basic....Done
0:0:0>Init MMU.....
0:0:0>NCU Setup and PIU link train....Done
0:0:0>L2 Tests....Done
0:0:0>Extended CPU Tests....-Chassis | major: Apr 21 10:51:09
ERROR: POST timed out. Not all system components tested.
Chassis | major: Host is running