Chapter 3
Server Diagnostics
3-21
3.3.2
Running the
showfaults
Command
The ALOM CMT
showfaults
command displays the following kinds of faults:
■
Environmental faults
– Temperature or voltage problems that might be caused by
faulty FRUs (power supplies, fans, or blower), or by room temperature or blocked
air flow to the server.
■
POST detected faults
– Faults on devices detected by the power-on self-test
diagnostics.
■
PSH detected faults
– Faults detected by the Solaris Predictive Self-healing (PSH)
technology
Use the
showfaults
command for the following reasons:
■
To see if any faults have been passed to, or detected by ALOM CMT.
■
To obtain the fault message ID (
SUNW-MSG-ID
) for PSH detected faults.
■
To verify that the replacement of a FRU has cleared the fault and not generated
any additional faults.
●
At the
sc
>
prompt, type the
showfaults
command.
The following
showfaults
command examples show the different kinds of output
from the
showfaults
command:
■
Example of the
showfaults
command when no faults are present:
■
Example of the
showfaults
command displaying an environmental fault:
sc>
showfaults
Last POST run: THU MAR 09 16:52:44 2006
POST status: Passed all devices
No failures found in System
sc>
showfaults -v
Last POST run: TUE FEB 07 18:51:02 2006
POST status: Passed all devices
ID FRU Fault
0 IOBD VOLTAGE_SENSOR at IOBD/V_+1V has exceeded
low warning threshold.
Summary of Contents for SPARC Enterprise T2000
Page 1: ......
Page 2: ......
Page 6: ......
Page 16: ...xiv SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 18: ...xvi SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 27: ...Preface xxv Reader s Comment Form ...
Page 43: ...Chapter 3 Server Diagnostics 3 3 FIGURE 3 1 Diagnostic Flow Chart flowchart ...
Page 106: ...4 12 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 152: ...5 46 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 173: ......
Page 174: ......