![Fujitsu SOFTUNE F2 MC-16 User Manual Download Page 226](http://html.mh-extra.com/html/fujitsu/softune-f2-mc-16/softune-f2-mc-16_user-manual_118473226.webp)
212
CHAPTER 2 DEPENDENCE FUNCTIONS
■
Notes on STEP Command
●
Exceptional Step Execution
When executing the instructions listed in the notes on the GO command as invalid breakpoints and abnormal
breakpoints, such instructions and the next instruction are executed as a single instruction. Furthermore, if
such instructions are continuous, then all these continuous instructions and the next instruction are executed
as a single instruction.
●
Step Execution that won't Break
Note that no break occurs after step operation when both the following conditions are met at one time.
•
When step instruction longer than 2 bytes length and last code ends at even address
•
When breakpoint already set at last address (This "already-set" breakpoint is an invalid breakpoint that
won't break, because it has been set at an address other than the starting address of an instruction.)
■
Controlling Watchdog Timer
It is possible to select "No reset generated by watchdog timer counter overflow" while executing a program
using the GO, STEP, CALL commands.
Use the ENABLE WATCHDOG, DISABLE WATCHDOG commands to control the watchdog timer.
- ENABLE WATCHDOG
:
Reset generated by watchdog timer counter overflow
- DISABLE WATCHDOG
:
No reset generated by watchdog timer counter overflow
The start-up default in this program is "Reset generated by watchdog timer counter overflow".
[Example]
>DISABLE WATCHDOG
>GO
Summary of Contents for SOFTUNE F2 MC-16
Page 2: ......
Page 3: ...FUJITSU SEMICONDUCTOR LIMITED F2 MC 16 FAMILY SOFTUNETM Workbench USER S MANUAL ...
Page 4: ......
Page 8: ...iv ...
Page 14: ...x ...
Page 342: ...328 CHAPTER 2 DEPENDENCE FUNCTIONS ...
Page 343: ...329 INDEX INDEX The index follows on the next page This is listed in alphabetic order ...
Page 352: ...338 INDEX ...
Page 354: ......