A26361-K881-Z102-4-7619
39
Hardware Installation
Installing/Removing the Rack Model into the Rack
Ê
Secure the end of the telescopic rail assembled with the bracket (HL) with
two screws M4 (2) on the support bracket in the rack.
Note with the fact that the two mounting springs are inserted in the appro-
priate openings of the support bracket (see figure 5 on page 34).
Ê
Adjust if necessary the length of the telescopic rails.
Ê
Secure the second telescopic rail with two screws M5 each in the rack at the
right support uprights.
Please note that the guide nubs of the telescopic rail next to the spring nuts
must fit into the holes in the support uprights.
Ê
Mount the DataCenter Rack cable management as described in the
Technical Manual of the DataCenter Rack.
Ê
Mount the server (see section “Installing the Server” on page 46).
Ê
Route the cables with the inserted server as described in the Technical
Manual of the DataCenter Rack.
4.4.3
Mounting into the Classic Rack
For mounting the server into the Classic Rack (19-inch) the following parts are
necessary:
–
two telescopic rails (assembled)
–
protective hose for fibre channel optical waveguide cable
I
General information are provided in the Technical Manual for the Classic
(19 inch) Rack (see also “Related Publications” on page 107).
Ê
Mark the position of the attachment points for the telescopic rails and for the
server (front panel) on the support uprights (four height units).
Refer to the information on the mounting aid.
Ê
Place the spring nuts to fasten the telescopic rails in the groove of the
support uprights at the marked attachment points.
Ê
Adjust the position of the nuts in the groove until they lock into the correct
position.