100
Options Guide
TX300 S6
Conversion from a floorstand model to a rack model
Ê
If necessary, lay the server on its right-hand side.
Get a second person to help you do this. The server can weigh around 25 -
40 kg (depending on the configuration).
Make sure that the server feet protrude over the table edge.
Figure 72: Removing the server feet
Ê
Remove the four screws on each of the server feet (1).
Ê
Remove the server feet.
I
The server feet are no longer required.
Figure 73: Removing the foot mounting rail
Ê
Loosen the three screws (1) of the foot mounting rail.
1
1
1
1
a
1
1
1
3
2
Summary of Contents for PRIMERGY TX300 S6
Page 1: ...Options Guide English PRIMERGY TX300 S6 Server Options Guide Edition August 2010 ...
Page 6: ...OptionsGuide TX300 S6 ...
Page 10: ...OptionsGuide TX300 S6 Contents ...
Page 18: ...18 OptionsGuide TX300 S6 Procedure ...
Page 92: ...92 OptionsGuide TX300 S6 Installing a BBU Expansion cards and BBU ...
Page 98: ...98 OptionsGuide TX300 S6 USB Flash Module UFM Further options ...
Page 114: ...114 OptionsGuide TX300 S6 Rack model Completion ...