Install all 2.5-inch PCIe SSDs SFF into their original slots in the PCIe SSD
extension box, see
"Installing 2.5-inch HDD/SSD modules" on page 218
▶
"Connecting the power cord" on page 82
.
▶
"Switching on the server" on page 83
.
7.8
Non hot-plug 2.5-inch HDD/SSD
7.8.1
Replacing a non-hot-plug 2.5-inch HDD/SSD
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Tools:
– Phillips PH2 / (+) No. 2 screw driver
– Phillips PH0 / (+) No. 0 screw driver
Preliminary steps
▶
"Suspending BitLocker functionality" on page 107
▶
"Shutting down the server" on page 49
▶
"Disconnecting the power cord" on page 50
▶
"Getting access to the component" on page 51
Removing the non-hot-plug cage
Locate the defective HDD/SSD, see
"Extended configuration with non-
hot-plug 2.5-inch HDDs/SSDs" on page 176
.
▶
Disconnect the cable from the non-hot-plug HDD/SSD 1.
▶
If applicable, disconnect the cable from the non-hot-plug HDD/SSD 2.
Hard disk drive (HDD) / solid state disk (SSD)
298
Upgrade and Maintenance Manual
TX2550 M5
Summary of Contents for PRIMERGY TX2550 M5
Page 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Page 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Page 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Page 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Page 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Page 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Page 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Page 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...