Removing a 2.5-inch HDD/SSD module
▶
Pinch the green locking clips and open the locking lever, see
▶
Pull the HDD/SSD module out a few centimeters.
▶
Wait about 30 seconds.
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
This period is necessary for the RAID controller to recognize that an
SSD module has been removed.
▶
Pull the HDD/SSD module completely out of its bay.
Installing a 2.5-inch dummy module
CAUTION
▶
If the removed HDD/SSD module is not replaced immediately,
always replace a dummy module into the unused HDD/SSD bay to
comply with applicable EMC regulations and satisfy cooling
requirements.
Figure 125: Installing a 2.5-inch HDD/SSD dummy module
▶
Push the dummy module into the empty bay until it engages.