50
Upgrade and Maintenance Manual
TX2550 M4
Basic hardware procedures
Ê
When using ServerView Operations Manager to toggle the ID indicator,
choose
Single System View
and press the
Locate
button.
Ê
Remember to switch off the ID indicator after the maintenance task has been
concluded successfully.
4.1.2
Determining the error class
The Local Service Concept (LSC) allows you to identify defective server
components. Failure events are assigned to one of two error classes:
–
Global Error
events that need to be resolved by maintenance personnel
–
Customer Self Service
(CSS) error events that may be resolved by
operating personnel
Global Error and CSS LEDs (see section
"Connectors and indicators" on
) indicate, if the defective component is a customer replaceable unit or
if maintenance personnel needs to be dispatched to replace the part.
I
The indicators also light up in standby mode and after a server restart
due to a power failure.
4.1.2.1
Global Error indicator
Ê
Check the Global Error indicator on the front panel or the I/O panel of the
server.
Ê
For more diagnostics, proceed as follows:
– Hardware errors:
Check the System Event Log (SEL), see section
– Software / agent related errors:
Check the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
I
For more information, see the "ServerView System Monitor" user
guide.
4.1.2.2
Customer Self Service (CSS) indicator
Ê
Check the CSS indicator on the front panel or the I/O panel of the server.
Summary of Contents for PRIMERGY TX2550 M4
Page 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Page 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Page 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Page 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Page 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Page 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Page 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Page 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Page 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Page 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...