366
Upgrade and Maintenance Manual
TX2550 M4
Processor (CPU)
11.3.2 Removing the heat sink
Figure 263: Removing the heat sink
Ê
Loosen the captive screws (circles) following the sequence described
below:
V
CAUTION!
Please do not use an electric screw driver.
1. Loosen the four captive screws one by one (in the sequence 4 to 1)
rotating them a half-turn each.
2. Loosen the captive screws 4 and then 3 rotating them two or three turns
each.
3. Repeat the step 2 until the screws 4 and 3 are completely loosened.
4. Loosen the captive screws 2 and then 1 rotating them two or three turns
each.
5. Repeat the step 4 until the screws 2 and 1 are completely loosened.
Ê
Lift the heat sink together with the CPU frame out of the chassis.
V
CAUTION!
Pay special attention not to damage any system board components
surrounding the CPU socket.
Summary of Contents for PRIMERGY TX2550 M4
Page 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Page 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Page 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Page 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Page 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Page 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Page 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Page 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Page 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Page 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...