TX2550 M4
Upgrade and Maintenance Manual
249
Hard disk drive (HDD) / solid state drive (SSD)
7.5.4.2
Removing the defective HDD/SSD backplane
Ê
Unlock and pull the 8x 2.5-inch HDD/SSD extension box out of its installation
bays, see section
"Removing the 8x 2.5-inch HDD/SSD extension box" on
Figure 161: Removing the HDD/SSD backplane (A)
Ê
Remove the four screws (see circles).
Figure 162: Removing the HDD/SSD backplane (B)
Ê
Fold up the HDD/SSD backplane (1) and at a slight angle, remove it from the
recesses in the HDD/SSD extension box (2).