218
Upgrade and Maintenance Manual
TX2550 M4
Hard disk drive (HDD) / solid state drive (SSD)
7.4.6
Installing 3.5-inch HDD modules
7.4.6.1
Preliminary steps
Ê
When working on a floorstand model, open the HDD bay cover, see section
"Removing the drive covers" on page 64
Ê
Locate the correct drive bay, see section
"3.5-inch HDD configurations" on
.
7.4.6.2
Removing a 3.5-inch HDD dummy module
Figure 136: Removing a 3.5-inch dummy module
Ê
Press both tabs together (1) and pull the dummy module out of its bay (2).
V
CAUTION!
Keep the dummy module for future use.
Always replace dummy modules into unused HDD bays to comply with
applicable EMC regulations and satisfy cooling requirements.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
tool-less
Summary of Contents for PRIMERGY TX2550 M4
Page 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Page 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Page 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Page 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Page 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Page 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Page 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Page 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Page 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Page 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...