TX200 S5
Operating Manual
43
Installing the hardware
Installing/removing the rack model
4.3
Installing/removing the rack model
V
CAUTION!
●
Please observe the safety information and notes on rack mounting in
chapter “Important notes” on page 27
●
Several people are needed to install / remove the server in the rack.
●
The rack can tip over if more than one unit is pulled out.
●
The server must not occupy the top height unit of the rack
(38 HU/42 HU PRIMECENTER rack and/or DataCenter rack), as
otherwise boards or system fans cannot be replaced even with the
plug-in module fully extended.
4.3.1
Rack system requirements
The rack systems from Fujitsu Technology Solutions, PRIMECENTER Rack
and DataCenter Rack, support the installation of PRIMERGY servers. Instal-
lation in most current rack systems from other manufacturers (3rd party racks)
is also supported.
To accommodate the ventilation concept and ensure proper ventilation, any
unused areas in the rack must be sealed using dummy covers.
The power is supplied via the multiple socket outlets fitted in the rack.
PRIMECENTER/DataCenter Rack
The main features of the rack systems from Fujitsu Technology Solutions are as
follows:
–
Support systems that can be mounted without tools
The support systems have a linear alignment feature to ensure that they can
be adjusted to different rack depths.
–
Enhanced cable management in the lateral rack area
The mounting of the rails in the different racks is described in the next sections.
Installation of the cable management is described in detail in the Technical
Manual for the respective rack.