8.3.6 Configuring and Deleting the Array System
■
How to Configure the Array System
This section describes how to configure the array system using onboard SCSI controller. Only level
RAID1 is configured.
`
Configure the array of two internal hard disks of the same model. The array system cannot be
configured on a different kind of hard disk.
`
If you connect any hard disk units with usage history to this server, format them at low level on another
system before connecting them to the server. For low-level formatting, refer to the manual supplied
with the other system to be used.
1
Start the SCSI Setup Utility.
2
Select the [<RAID Properties>] submenu from the [<Adapter Properties>]
menu, and press the [Enter] key.
[RAID Properties] submenu window appears.
3
Select [Array Disk?] of which [SCSI ID] is [0], and press the [+] key to change
[No] to [Yes].
When the [+] key is pressed, the following message appears.
4
Press the [F3] key.
5
Select [Array Disk?] of which [SCSI ID] is [1], and press the [+] key to change
[No] to [Yes].
`
The following message may appear which indicates that the data are in the target disk. The
data in the hard disk are deleted when the array system configured.
Press the [Delete] key to delete data and configure the array system.
6
Press the [Esc] key to display the [Exit] menu.
7
Select [<Save changes then exit this menu>] and press the [Enter] key.
F3 - Keep Date(Create 2 disk array)
Delete - Erase Disk(Create 2 to 6 disk array)
WARNING:Data on disk will be LOST!
Hit DELETE if data loss OK, any other key to can-
cel
Summary of Contents for primergy TX150
Page 112: ...112 Chapter 3 OS Installation Using ServerStart ...
Page 140: ...140 Chapter 4 Manual OS Installation ...
Page 174: ...174 Chapter 5 Operations after OS Installation ...
Page 182: ...182 Chapter 6 High Reliability Tools ...
Page 214: ...214 Chapter 7 Installing Internal Options ...
Page 248: ...248 Chapter 8 Configuring Hardware and Utilities ...
Page 300: ...300 D Recycling ...
Page 304: ...304 ...