TX150 S8 / TX200 S7
Upgrade and Maintenance Manual
89
Basic software procedures
Ê
The system will detect the USB stick.
I
If the BIOS cannot identify the USB stick, the pop-up message
Failed to boot for Emergency flash. Please Reset now.
will show up in the center of the screen.
Ê
Choose the
Recovery_L
option from the update tool menu to start the iRMC
update process.
V
CAUTION!
Do not interrupt the iRMC upgrade process after it has started. If the
process is interrupted, the iRMC BIOS may be permanently
corrupted.
I
If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
Ê
Shut down the server by pressing the power On / Off button.
Ê
Disconnect the server from the mains to exit the iRMC recovery state.
5.2.2
Verifying system information backup / restore
To avoid the loss of non-default settings when replacing the system board, a
backup copy of important system configuration data is automatically stored from
the system board NVRAM to the Chassis ID EPROM. After replacing the
system board the backup data is restored from the Chassis ID board to the new
system board.
In order to verify whether the backup or restore process has been successful,
check the System Event Log (SEL) using the ServerView Operations Manager
(see also section
"Viewing and clearing the System Event Log (SEL)" on
After replacing the system board
Ê
Check the SEL log files as described in section
System Event Log (SEL)" on page 97
to verify whether the backup data on
the Chassis ID EPROM has been restored to the system board:
Chassis IDPROM: Restore successful
Summary of Contents for PRIMERGY TX150 S8
Page 22: ...Upgrade and Maintenance Manual TX150 S8 TX200 S7 Contents ...
Page 108: ...108 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Basic software procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Power supply units ...
Page 184: ...184 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Hard disk drives solid state drives ...
Page 196: ...196 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Fans ...
Page 274: ...274 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Processors ...
Page 348: ...348 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Front panel and external connectors ...
Page 388: ...388 Upgrade and Maintenance Manual TX150 S8 TX200 S7 System board and components ...