TX150 S8 / TX200 S7
Upgrade and Maintenance Manual
425
Appendix
I
Note on the onboard LAN controller
The separate management LAN connector is used as a management
interface (iRMC S3) and is prepared for operation with the Remote
Management. Optionally LAN connector 1 can also be used for iRMC S3
server management.
17.2.1.5 PSU indicator (only hot-plug PSUs)
Figure 335: PSU indicator
2
LAN
link / transfer
indicator
green on
LAN connection established
off
no LAN connection
green flashing
data transfer in progress
3
LAN speed
indicator
yellow on
traffic a transfer rate of 1 Gbit/s
green on
traffic a transfer rate of 100 Mbit/s
off
traffic a transfer rate of 10 Mbit/s
Indicator Status
Description
1
PSU
operating
status
green on
Server is switched on and functioning
properly
green flashing
Server is switched off, main voltage is
present (Standby mode)
orange on
PSU failure (over / under voltage, over
temperature or fan failure)
orange flashing Overload warning
Indicator Status
Description
Summary of Contents for PRIMERGY TX150 S8
Page 22: ...Upgrade and Maintenance Manual TX150 S8 TX200 S7 Contents ...
Page 108: ...108 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Basic software procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Power supply units ...
Page 184: ...184 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Hard disk drives solid state drives ...
Page 196: ...196 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Fans ...
Page 274: ...274 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Processors ...
Page 348: ...348 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Front panel and external connectors ...
Page 388: ...388 Upgrade and Maintenance Manual TX150 S8 TX200 S7 System board and components ...