TX150 S8 / TX200 S7
Upgrade and Maintenance Manual
269
Processors
11.5.2.2 Installing the heat sink
Figure 186: Installing the heat sink
Ê
Align the heat sink as shown with the cooling fins matching the direction of
the airflow (see airflow label).
Ê
Carefully seat the heat sink on the four threaded holes as shown (see close-
up).
Ê
Fasten the four captive screws on the heat sink in a crossover pattern
(screw torque: 1.0 Nm, not applicable for the Japanese market) (1-4).