142
Upgrade and Maintenance Manual
TX150 S8 / TX200 S7
Hard disk drives / solid state drives
7.2.3
Installing 2.5-inch HDD / SSD modules
7.2.3.1
Preliminary steps
Ê
"Removing accessible drive and HDD bay covers" on page 60
Ê
Locate the correct drive bay as described in section
7.2.3.2
Removing a 2.5-inch HDD / SSD dummy module
Figure 67: Removing a 2.5-inch dummy module
Ê
Press both tabs together (1) and pull the dummy module out of its bay (2).
V
CAUTION!
Save the dummy module for future use.
Always replace dummy modules into unused HDD / SSD bays to
comply with applicable EMC regulations and satisfy cooling
requirements.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
tool-less