Upgrade and Maintenance Manual
TX150 S8 / TX200 S7
Basic software procedures
Ê
Save and close the definition file.
Ê
For the changes to take effect, you need to reboot the network by entering
the following command:
# service network restart
I
If the system board or network controller offers multiple LAN ports, it is
necessary to update the remaining
ifcfg-eth<x>
definition files
accordingly.
Ê
Update the NIC configuration file to reflect the new card sequence and MAC
address.
5.2.13 Enabling BitLocker functionality
If BitLocker Drive Encryption has been disabled or suspended for maintenance
purposes (see section
"Disabling or suspending BitLocker functionality" on
), it has to be re-enabled to complete the service task.
I
If BitLocker Drive Encryption has been disabled or suspended prior to
replacing components you won't be asked for a recovery key when
rebooting the server after the maintenance task. However, if BitLocker
functionality has not been disabled or suspended, Windows will enter
recovery mode and ask you to input recovery key for further booting.
Ê
In this case, ask the system administrator to enter the recovery key in
order to boot the operating system.
Ê
Ask the system administrator to enable BitLocker-protection on the
operating system drive, using the BitLocker setup wizard available either
from the Control Panel or Windows Explorer.
Ê
Open BitLocker Drive Encryption by clicking the
Start
button, clicking
Control Panel
, clicking
Security
, and then clicking
BitLocker Drive
Encryption
.
I
Administrator permission required: If you are prompted for an
administrator password or confirmation, type the password or
provide confirmation.
Ê
To enable or resume a temporarily disabled or suspended BitLocker,
click
Turn On BitLocker
.
Ê
Follow the instructions in the BitLocker Setup wizard.
Summary of Contents for PRIMERGY TX150 S8
Page 22: ...Upgrade and Maintenance Manual TX150 S8 TX200 S7 Contents ...
Page 108: ...108 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Basic software procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Power supply units ...
Page 184: ...184 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Hard disk drives solid state drives ...
Page 196: ...196 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Fans ...
Page 274: ...274 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Processors ...
Page 348: ...348 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Front panel and external connectors ...
Page 388: ...388 Upgrade and Maintenance Manual TX150 S8 TX200 S7 System board and components ...